Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Parallel light path design can measure 100mm thickness material, accuracy +/- 1%, resolution of 0.001%, support field and fixed station two Measurement mode, suitable for a variety of Optical inspection material detection.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.
Imported linear slide rail to ensure parallel accuracy 0.1 +/- 0.01mm, blade Hardness can be cut steel, sampling thickness 0~ 5mm, special treatment die durable and easy to restore accuracy.
It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.
Measurable six paraMeters including UV barrier rate, visible light transmittance, infrared 950nm, 1400nm, Full IR and SHGC, using parallel light design, test accuracy +/- 2%, suitable for large Film thickness Glass, with real-time dynamic self-calibrating function.
Illuminant lighting luminance adjustable, equipped with swing Abbe condenser numerical aperture 1.30, provide plaster lambda and quartz wedge compensator, support 360 degree swirl/spin table.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving system, the light transmitance haze accuracy is up to 0.01%, with A/C/D65 three light sources and vertical-lying dual-use observation mode, support USB interface data export, LED light source long life fast start.
Using dual motors and driving the male rotation independent control, compatible with a wide range of materials and a single Processing capacity; 20 sets of formulas can be set up with 10 segments in each group to adapt to a variety of materials; complete protection functions, data can be exported and traced.
16 200ml samples can be processed simultaneously, 4-sided Glass is easy to observe, independent heating prevents backflow to avoid cross-contamination, supports 0-350rpm Rotation speed and 0-100 ℃ water Bath heating, flexible operation to adapt to complex experimental needs.
Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.
The device places the test plate in parallel in the wind tunnel, the wind speed control accuracy is 3 +/- 0.3m/s, the drying time is automatically controlled, and the surface crazing can be visually inspected, which is suitable for the evaluation of coating anti-crack performance.
Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.