Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.
Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.
Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.
Using imported wire Rod accuracy of 1 μ m, Spreader rate 5~ 200mm/s adjustable, support scraper and wire Rod two Spreader mode, Heating Temperature Uniformity +/- 3 ℃, suitable for a variety of substrate Film thickness treatment.
Microcomputer PID temperature controller to ensure accurate and reliable temperature control, Temperature Uniformity +/- 3%, hot air circulation system to improve Temperature uniformity, independent temperature limit alarm system to ensure experimental safety.
Speed range 0-1500rpm, Processing capacity 5-30L, using high-performance variable frequency motor to achieve low noise and smooth operation, support a variety of stirring forms and lifting methods to adapt to different process requirements.
Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.
Spreader thickness range 0.01~ 10mm, coating speed 5~ 180mm/s, using removable drawdown blade and import bar to ensure Spreader uniformity and High Accuracy control, improve experimental repRoducibility.
Using scraping method to achieve 0.005-3mm wet film thickness, Spreader accuracy of +/- 5%, equipped with hot air circulation Oven and automatic constant tension control to ensure Spreader uniformity and Stability.
Maximum load 0.5KN, designed for small force test, compact structure, easy operation, ensure test Stability and Repeatability.
Using swirl/spin design, light weight and easy to move, can effectively improve the Measurement accuracy and prevent the instrument from falling, suitable for small workpiece measurement scenarios.
Impact energy 2.7mJ, Impact device mass 75g, small damage to the measured surface, does not damage the hardened layer, suitable for measurement of small and thin parts, the minimum thickness of the specimen is 1mm, and the minimum depth of the hardened layer is 0.2mm.
Fast sterilizing in ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, the built-in over-temperature protection device, and the stainless steel liner container ensures safety and durability.
Maximum load 0.5KN, compact structure, reliable clamping, suitable for a variety of small sample testing, easy to operate.