High-precision ultrasonic thickness Gauge.

High-precision ultrasonic thickness gauges utilize the principle of ultrasonic wave propagation and reflection in materials to calculate thickness by measuring the round-trip time of sound waves. They are used to measure the thickness of coatings, plastics, metals, and other materials, and are employed in industrial quality inspection to monitor material uniformity and wear conditions.

Instruments

Featuring a professional timing chip with a resolution as high as 0.001mm, a measurement range from 0.8mm to 800mm, and equipped with gain switching, QC judgment, and automatic statistical functions, the streamlined body ensures a comfortable grip.

$ 248.00

Measurement range 1.5~ 200mm, accuracy +/- 0.5% n + 0.2, 5MHz Frequency Probe, contact temperature 0~ 50 ℃, suitable for a variety of material thickness detection.

$ 154.00

Using the principle of ultrasonic thickness measurement, Display resolution up to 0.01mm, with Probe zero point Adjustment, support Data storage and backlight display, can be used in dark environment.

$ 248.00

Using 320 × 240 color display, support standard, MIN Minimum, differential value and other Measuring methods, Measurement range 1.4~ 200mm, resolution up to +/- 0.01mm, with Automatic calibration and USB data output.

$ 2255.00

Using non-penetrating ultrasonic technology, Measurement range 0.8~ 300mm, accuracy of 0.01mm, support four Measuring methods and 5000 data storage, with Automatic calibration and high-speed measurement function.

$ 1093.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Using ultrasonic measurement technology, Measurement range 0.75~ 300mm, error +/- (1% H + 0.1) mm, support single point and scan mode, with Automatic calibration and sound speed reverse measurement function, suitable for harsh environment.

$ 315.00

Equipped with a professional timing chip, it offers a resolution of up to 0.001mm and a measurement range from 0.8mm to 800mm. With features such as gain switching, QC judgment, and automatic statistics, it is suitable for rapid and precise thickness measurement of various materials.

$ 312.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, adjustable weighing speed of fast, medium and slow, and equipped with RS-232 interface for data connection.

$ 637.00

Suitable for 300 ℃ high temperature material thickness measurement, range 2.0~ 100mm, diaMeter 14mm, minimum diaMeter 30mm, 5MHz Frequency to achieve accurate measurement.

$ 199.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Imported High Accuracy Electrochemical sensor, detection limit up to 0.001ppm. Support 4-20mA, RS485 and other signal output, with overvoltage, lightning protection, short circuit and other multiple protection and automatic recovery functions.

$ 582.00

Using ultrasonic technology nondestructive measurement, up to 3 layers of coating system measurement range 50~ 3800 μ m, error +/- 3%, with weatherproof design and high capacity Data storage function.

$ 3724.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
MIT Folding Endurance Tester is used for high-frequency folding tests.
This article introduces the application of the MIT folding endurance tester in high-frequency folding tests. High-frequency folding tests simulate the actual usage of materials under rapid and repeated folding, placing high demands on the instrument, requiring it to possess high frequency, high precision, and stability.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.