Coulometric Method Water Content Analyzer

The Coulometric Karl Fischer Titrator operates based on the Karl Fischer reaction, which quantitatively detects the moisture content in samples through the electrolytic generation of iodine. The instrument electrolytically produces iodine to react with water, and the moisture content is calculated based on the amount of electricity consumed during electrolysis. It is used for moisture detection in raw materials and finished products in industries such as coatings and inks.

Instruments

The thermal weight loss method is used to measure carbon black content, the operating temperature can reach 990 ° C, and the 7-inch Touchscreen is equipped to realize one-button calculation, support segmented paraMeter setting, and the Furnace body separation design has better heat dissipation.

$ 1848.00

The samples were treated by acid-base cooking method, and 6 samples could be measured each time. The repeatability error of the absolute value of crude fiber content below 10% did not exceed 0.4%, and the determination time was about 100 minutes.

$ 912.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Surface Water Absorbency was measured by Cobb test method, test area 100cm ² accuracy +/- 0.2cm ², liquid height 10mm, pressure roller mass 10kg to ensure uniform pressure, Cup body 316 stainless steel corrosion resistance.

$ 624.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

The imported cold light source does not need to be preheated for 100,000 hours, the detection limit is 0.01mg/L Sensitivity is high, the standard and continuous Measurement mode are supported, and the digestion Colorimetric integrated tube is safe and fast to operate. It can store 4000 sets of data and support a variety of transmission methods.

$ 816.00

Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.

$ 567.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Using Spectrophotometric method, specs-trophotometry to detect nickel content, Measurement range 0.00-7 g/L, accuracy +/- 0.10g/L, equipped with LED@575nm Illuminant, easy to operate without complex pretreatment, suitable for rapid batch detection needs.

$ 215.00

4 groups of samples can be tested at the same time, using PID temperature control accuracy of 0.1 ℃, support segmented program heating, one key automatic calculation of carbon black and ash content, open the lid structure heat dissipation fast.

$ 2784.00

The stainless steel water jacket structure ensures durability, and the water-proof heating method makes the Temperature Uniformity reach +/- 1 ° C, which can still maintain thermostatic after power failure. The microcomputer temperature control system has multiple safety protection and 0.1 ° C temperature resolution.

$ 819.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.