Double-Bath melting point apparatus

The dual-bath melting point apparatus uses two separate baths to heat the sample and provide a stable thermal environment, respectively, while monitoring the phase transition temperature during sample melting with temperature sensors. It is used to determine the melting point range of solid substances and is routinely employed in the chemical, pharmaceutical, and materials industries to assess the purity and thermal stability of substances.
Selection
When selecting, consider matching the sample characteristics with the heating temperature range, the clarity of the observation window for visual phase change detection, the temperature control accuracy affecting data reliability, the simplicity of the operation interface related to ease of use, maintenance requirements involving long-term operational costs, and referencing existing laboratory space dimensions to accommodate the instrument size.

Terms

Standards

Instruments

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.

$ 1526.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.

$ 5754.00

2 samples can be measured at the same time, using platinum temperature sensor temperature control accuracy 0.1 ℃, heating rate 0.1-10 ℃/min, automatic recording of the experimental process and support playback.

$ 9885.00

With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.

$ 1501.00

With 0.2~ 5 ℃/min eight linear heating rate control, Temperature resolution of 0.1 ℃, Support Capillary Method and Cover Slip Method Measurement mode, Can observe 40X~ 100X zoom sample melting process.

$ 2244.00

Using photoelectric detection technology to automatically identify the initial and final melting points, equipped with Platinum Resistance Sensor to ensure +/- 0.5 ℃ accuracy, support eight linear heating rate and automatic storage function, no manual monitoring can complete the measurement.

$ 1116.00

Using photoelectric automatic detection technology, the temperature resolution reaches 0.1 ℃, the temperature control system applies PID regulation and PWM technology to improve the measurement accuracy and reliability, and supports automatic recording of initial melting and final melting results.

$ 1855.00