Furnace Temperature Control System

The furnace temperature control system collects real-time temperature data inside the furnace via sensors, compares it with the set value through the controller, and adjusts the power of the heating element to maintain temperature stability. It is used in equipment such as ovens and vulcanizing machines to ensure process conditions like material curing and drying.
Selection
When selecting, it is necessary to match the process temperature range and accuracy requirements, confirm the sensor type and installation method, check the response speed of the control algorithm, consider equipment compatibility and communication interfaces, evaluate the protection level to suit the on-site environment, and verify the power specifications and safety certifications.

Terms

Standards

Instruments

Maximum temperature up to 1200 ℃, temperature control accuracy 1 ℃, with 30 program settings and over-temperature protection function, full range programmable automatic control of heating thermostatic, Furnace size 400 * 250 * 160mm.

$ 1272.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

The refractory brick Furnace has excellent thermal insulation performance, is equipped with 50-stage program temperature control system, Temperature Fluctuation +/- 2 ℃, supports over-temperature alarm and timing function, and the Furnace volume is 7.2L to ensure the safety and stability of the experiment.

$ 1009.00

Adopt aluminum silicate ceramic fiber Furnace, heating rate ≤ 45 ℃/min, temperature control accuracy +/- 1 ℃, support multi-stage programmable control, with over-temperature protection and abnormal alarm function, Furnace body double-decked design with chill down fan.

$ 3038.00

The refractory brick Furnace has good thermal insulation performance, temperature control accuracy +/- 2 ℃ and over-temperature protection, with power failure recovery function and 1-9999 minutes Timer Range to ensure the safety and reliability of the experiment.

$ 1054.00

High aluminum Furnace wear-resistant high temperature, 4-sided heating evenly; PID self-tuning temperature control accuracy +/- 2 ℃, over-temperature automatic protection; compact overall structure, convenient and safe operation.

$ 567.00

The double-decked shell structure is used with the Air-Cooled circulation system to achieve rapid heating and surface low temperature; the 51-stage program temperature control ensures +/- 1 ℃ accuracy, the Furnace size is 500 * 400 * 400mm, and the temperature field is Balanced and energy-saving and efficient.

$ 5350.00

It only takes 25 minutes to heat up to 1200 ° C, the temperature control accuracy is +/- 1 ° C, the ceramic fiber Furnace and air insulation structure are used, the surface temperature is only about 50 ° C, and it has multi-step programming function.

$ 1947.00

Operating temperature up to 1400 ℃, Furnace volume 80L, using aluminum oxide fiber Furnace and silicon carbon Rod heating, with double chill down system and accurate Gas flow rate control, support inert atmosphere sintering process.

$ 6012.00

Adopt high aluminum liner and upper and lower left and right 4-sided Heating mode, temperature control accuracy up to +/- 2 ℃, Furnace volume 16L, with over-temperature alarm and automatic cut-off function, support intelligent segmented temperature control.

$ 719.00

Using double-decked shell structure and aluminum oxide Furnace material, temperature control accuracy +/- 1 ℃, heating rate ≤ 20 ℃/min, temperature field Balance and energy saving, low surface temperature.

$ 6948.00

Three-sided heating method to ensure uniform temperature, PID microcomputer and precision Sensor combination to achieve +/- 5% ℃ temperature control accuracy, closed aluminum silicate Furnace to reduce heat loss, support 0~ 9999 minutes timing and a variety of operating modes.

$ 990.00

Maximum temperature 1000 ℃, Furnace volume 2L, three-sided heating method with stage heating, PID control to ensure temperature fluctuation +/- 5%, K-type Thermocouple monitoring, with over-rise alarm and menu lock function.

$ 477.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

Adopt industrial PID self-tuning temperature control technology, Temperature Fluctuation +/- 2 ℃, display accuracy 1 ℃. Up, down, left and right 4-sided heating structure, Furnace volume 30L, with over-temperature protection and automatic timing function.

$ 751.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Friction coefficient meter adjusts the control of film slip agent addition.
This article introduces how to use a coefficient of friction meter to adjust the amount of slip agent added in film production.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Preparation of composite films by coating mechanism for electrical performance experimental characterization
This article introduces the method of preparing composite films using a film coating machine and testing their electrical properties. The film coating machine evenly spreads the slurry with a blade, controlling thickness and uniformity. The preparation process includes raw material preparation, substrate treatment, coating, and curing.