Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.
Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.3 ℃, automatic timing function to ensure accurate and reliable testing, compact structure and easy handling.
The width of the groove is 2.5 times the maximum particle size of the coal sample, the slope of the groove is not less than 60 degrees, and it has multi-point shrinkage performance, which can effectively improve the sample representation and is suitable for the shrinkage of samples of different particle sizes.
With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.
150W Philips infrared lamp, peak wavelength 950nm, temperature measurement accuracy +/- 0.5 ° C, insulation accuracy +/- 2%, can quickly compare the insulation performance of different materials, the test time is only 1 minute.
Film Film thickness 22.9μm, Spreader width 30cm, wear-resistant stainless steel material, molding process, suitable for low viscosity glue and thermal glue experimental Spreader.
Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.
Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.
Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.
The transient planar heat source method is used, the test time is not more than 160 seconds, the Sensitivity is 0.00001, and the thermal conductivity of 0.0001 to 50W/(m * K) can be measured. It supports a variety of morphological samples and meets international standards.
The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.
Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.
Measurement range 10~ 16000mN, resolution 0.1mN, pneumatic fixture to ensure stable clamping, thermal printer real-time output test data, suitable for a variety of sheet material Tear strength detection.
Temperature resolution is up to 0.1 ℃, heating rate is adjustable from 0.1 ℃ to 20 ℃/min, hot stage method and visual measurement are supported, which is suitable for the study of thermal characteristics of trace samples.
The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.