High-temperature Thermostatic Oil Bath

High-temperature oil baths create a constant temperature environment by electrically heating heat transfer oil, which is used for material heat resistance testing and chemical reaction heating. The medium temperature of the oil bath can reach up to 300℃, ensuring uniform heat transfer, making it suitable for applications such as laboratory sample heating and viscosity determination.
Selection
When selecting, consider matching the temperature range with experimental requirements, ensuring the flash point of the oil bath medium is higher than the target temperature. Pay attention to whether the heating power and tank capacity meet the sample size, and check temperature control accuracy and safety features such as overheating protection. Prioritize heat transfer oils with good chemical stability.

Terms

Standards

Instruments

With water and oil dual-use function, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, equipped with multiple Safety protection devices.

$ 677.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Adopt microcomputer PID temperature controller, temperature control accuracy +/- 0.5 ℃, over-temperature sound and light tracking alarm to protect samples, stainless steel liner shell anti-corrosion and easy to clean, support internal and external circulation.

$ 680.00

Temperature range RT +~ 300 ℃, Tank volume 3L, stainless steel material high temperature corrosion resistance, intelligent integrated circuit to achieve accurate temperature control, LED display intuitive and clear.

$ 190.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 1 ℃, equipped with imported pumps to ensure uniform temperature, strong corrosion resistance, compact structure, long service life.

$ 522.00

Temperature control accuracy +/- 0.5 ℃, Temperature range 20~ 200 ℃, equipped with microcomputer PID controller and over-temperature sound and light alarm function to ensure sample safety, stainless steel liner easy to clean and corrosion resistance.

$ 798.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

Temperature control accuracy of +/- 1 ℃, Temperature range RT +~ 299 ℃, stainless steel studio water Tank, excellent corrosion resistance, digital display automatic temperature control, easy and reliable operation.

$ 414.00

With 0.0001 ℃ high resolution display and +/- 0.005 ℃ Temperature Uniformity, the use of heat-free centrifugal pump to avoid self-heating effects, support water-oil dual-use Temperature range up to 300 ℃.

$ 1335.00

The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.

$ 148.00

The stainless steel material is resistant to high temperature and corrosion, Temperature range RT +~ 300 ℃, double hole design can be tested at the same time, and the temperature control reading of intelligent integrated circuit is intuitive and accurate.

$ 199.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, temperature control accuracy 0.01 ℃; no heat centrifugal circulation pump to avoid self-heating effect, porous U-shaped return design to achieve uniform turbulence; Equipped with multiple Safety protection and external circulation to establish a second thermostatic field.

$ 617.00

With 0.0001 ℃ high resolution display and +/- 0.005 ℃ Temperature Uniformity, the use of non-heat centrifugal circulation pump to ensure uniform insulation field, support water and oil dual-use Temperature range up to 300 ℃.

$ 1067.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.