ElectRode Method Residual Chlorine Analyzer

The electrode method residual chlorine analyzer generates a potential difference through the reaction between the electrode and residual chlorine in water, and measures the change in potential to calculate the residual chlorine concentration. It is used to monitor the disinfection effectiveness of drinking water, swimming pool water, and industrial circulating water to ensure water quality safety.
Selection
When selecting, consider that the measurement range covers usage requirements, the electrode material is corrosion-resistant, and it has temperature compensation functionality. Check the instrument calibration cycle and electrode replacement frequency, and match the on-site installation method and protection rating.

Terms

Standards

Instruments

Designed for residual chlorine ElectRode Reagent, 250ml size, provides stable ionic strength adjustment to ensure fast and accurate ElectRode Response in the measurement process, suitable for various water quality testing environments.

$ 127.00

Designed for residual chlorine ElectRode, with a capacity of 250ml, it provides stable calibrating performance, ensures reliable measurement results, and is suitable for a variety of water quality analysis scenarios.

$ 110.00

Iodine Reagent Formula specially designed for residual chlorine ElectRode, 250ml Encasement to meet routine testing needs, with ElectRode can improve Measurement accuracy and Stability, suitable for a variety of water quality environments.

$ 127.00

Using BNC connector design, equipped with 60mL calibrated solution and residual chlorine regulator, replaceable membrane to extend service life, suitable for water quality monitoring.

$ 309.00

Measurement range covers 0~ 5mg/L residual chlorine total chlorine and 0~ 10mg/L chlorine dioxide, support 100 measurements, suitable for water quality testing, easy and fast operation.

$ 128.00

Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.

$ 622.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

8Nm Narrowband Interference filter and LED Illuminant, wavelength accuracy +/- 1nm, support residual chlorine and total chlorine 0.00-5 mg/L Measurement range, built-in reaction Timer and 50 sets of Data storage, with IP67 waterproof performance.

$ 632.00

Measurement range 0~ 5mg/L, can carry out 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate quickly detect residual chlorine and total chlorine content.

$ 122.00

Measurement range 0~ 5mg/L, support 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate and quickly detect residual chlorine content.

$ 114.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Using micro-processing technology and high Reliability integrated circuit, with data nonlinear processing and smoothing function, fast automatic multi-point correction, Measurement range residual chlorine 0~ 2.5mg/L, chlorine dioxide 0~ 5.0mg/L, Repeatability 2%, to ensure long-term stable work.

$ 428.00

Measurement range 0~ 5mg/L, support residual chlorine and chlorine dioxide dual paraMeter detection, a single package can complete 100 measurements, supporting special instruments to use convenient and fast.

$ 122.00

Colorimetric measurement using DPD method, Measurement range of 0.00~ 5.00mg/L, providing 100 tests to ensure accurate determination of free chlorine concentration.

$ 151.00

Measurement accuracy is ensured by 515nm wavelength Illuminant, Measurement range 0.02-3 mg/L, support 200 sets of Data storage and IP65 protection, lithium battery power supply is convenient for field use.

$ 385.00

Articles

Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
The role of the coating machine in the preparation of fuel cell membrane electrode assemblies
The film coating machine is a key equipment for preparing the membrane electrode, the core component of fuel cells. It evenly coats a catalyst-containing slurry onto a substrate using techniques such as blade coating, slot-die extrusion, or spraying, forming a catalytic layer ranging from a few micrometers to several tens of micrometers in thickness.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.