Quickly calculate the dew point through the wet-bulb temperature Measurement principle, support direct reading of relative humidity, integrated temperature unit conversion function, easy operation without complicated settings.
Dual thermoMeter design can simultaneously measure wet-bulb temperature, equipped with special conversion ratio calculation tool, Temperature Measurement range covering -5 to 50 ℃, Humidity Measurement range 10-100% RH.
Measurement range 0-14.00 pH, temperature adaptability 0-80 ℃, bulb sensitive film with filling design, suitable for organic sample analysis.
The friction speed is adjustable from 21 to 106 rpm, and the friction load is 908g or 1810g. It supports a variety of test modes such as dry grinding, wet grinding, and decolorization changes. The automatic shutdown function ensures accurate control of the number of tests.
Capacitive polymer film Humidity Sensor and semiconductor temperature sensor are used. The temperature error is +/- 0.2 ℃, Humidity error is +/- 2.0%, and wet bulb, dew point, dry bulb temperature switching and 99 groups of Data storage are supported.
Using high temperature dry heat technology, temperature control accuracy of +/- 1 ℃, rapid heating and over-temperature protection function, studio volume 70L, easy and safe operation.
Simultaneous measurement of four paraMeters, Sampling time of only 0.4 seconds, humidity error of 2.5% +/- 1% RH, automatic recording of extreme and final values, anti-interference technology to ensure precise measurement.
Single salt bridge structure and bulb sensitive membrane are adopted. Measurement range is 0-14pH and temperature adaptability is 0-100 ℃.
With dry grinding and wet grinding dual test function, friction Frequency four-speed adjustable (21/42/85/106cpm), support 0~ 99999 automatic shutdown, in line with JIS-5071-1 and other standard requirements.
With four-speed Adjustable Friction Frequency (21-106cpm), support 2lb/4lb friction load, can complete dry grinding, wet grinding, decolorization changes and other tests to meet a variety of standard requirements.
Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.
Equipped with industrial-grade powerful motor, Speed range 16000-28000rpm, with wet and dry two-in-one cutter head design, double automatic protection circuit to ensure safe operation, strengthen the transparent plastic steel container heat resistance is not fragile.
The use of diamond sanding needles can flatten the surface of the grinding wheel, improve the utilization rate of abrasive wheels, and is equipped with a water supply system to support wet grinding and dry grinding. The size of abrasive wheels is about 250 × 30 × 32mm, and the Rotation speed is 1400rpm.
Adopt high temperature dry heat technology, Temperature range RT + 10~ 250 ℃, Input Power 1550W, with High Accuracy Microcomputer LCD display, automatic over-temperature protection and forced convection design, shorten disinfection time.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.