With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.
Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.
With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.
Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.
Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.
Temperature range of -40~ 150 ℃ and 20~ 98% Humidity control, anti-condensation design of laminated Glass viewing window, support multi-stage program editing and fast slope control, meet a variety of standard test requirements.
Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.
Temperature range -40~ 150 ℃, Humidity range 20~ 98% RH, with multi-stage program editing and fast slope control function, double-decked air tight and sweat-proof viewing window design.
The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.
Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.
Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.
Temperature range -30~ 100 ℃, temperature control accuracy +/- 0.1 ℃, with internal and external circulation function, no heat circulation pump is used to avoid its own heat generation affecting the temperature field of the tank, large screen backlit LCD display can independently control heating and cooling internal and external circulation, multiple safety protection including over-temperature alarm and low level protection.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet the needs of complex experiments.