Laboratory Ultrapure Water Purifier

Laboratory ultrapure water systems remove particles and ions through pretreatment, followed by deep purification using reverse osmosis membranes and ion exchange resins, and finally sterilization with ultraviolet lamps. They are used to produce water free of impurities, meeting the water quality requirements for experiments, and are applied in analytical testing and reagent preparation.
Selection
When selecting, consider the water consumption matching the water production rate, determine the water quality grade based on experimental needs, pay attention to the replacement cycle and cost of consumables, check the equipment's footprint, and ensure that maintenance operations are simple.

Terms

Standards

Instruments

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

Suitable for ultra-low conductivity water sample measurement, Glass grinder liquid interface design, pH Measurement range 0-11, Temperature range 0-80 ℃, support can add liquid reference solution.

$ 273.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

The water pRoduction rate reaches 10L/h, the water intake Flow velocity is 1.0L/min, and the RO membrane intelligent anti-scale washing and automatic domestic circulation system are used to ensure stable water quality and meet the high standard requirements of the laboratory.

$ 2300.00

With five-point pH automatic calibration and USP standard conductivity analysis, support linear nonlinear temperature compensation, Data storage up to 50,000/group, Capacitive touch interface easy to operate.

$ 2211.00

The water pRoduction rate is 10L/h, and the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, providing 18.25MΩ. cm ultra-pure water quality, supporting multiple water intake modes and intelligent control functions.

$ 4027.00

The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.

$ 3543.00

With 40L/H water pRoduction capacity and 18MΩ · cm resistivity ultrapure water output, the 7-inch touchscreen displays three-way water quality and temperature in real time, supports automatic circulation, consumables reminder and disinfection functions, ensuring stable water quality and low bacterial contamination.

$ 4408.00

The resistivity of the pRoduced water is greater than 18.2MΩ · cm, the water pRoduction capacity is up to 100L/H, and it is equipped with a 5.1-inch LCD screen to display water quality and temperature in real time. It supports automatic circulation and disinfection functions, effectively prolonging the life of consumables.

$ 3097.00

With 80L/H water pRoduction capacity and 18.2MΩ · cm ultra-pure water quality, it supports regular automatic circulation and consumable life monitoring. It can disinfect and display three-way water quality with one click, prolong the service life of the ultra-pure water bag, and achieve efficient online monitoring.

$ 2834.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Filtrate efficiency ≥ 99.97% for ≥ 0.5μm particles, wind speed 1.2~ 2m/s adjustable, trend thousand cleanliness, with moving runner and adjustable jack, flexible to adapt to different working position needs.

$ 1865.00

Filtrate efficiency ≥ 99.97% For particles ≥ 0.5μm, the average wind speed is adjustable from 1.2 to 2m/s, the trend purification level is up to 1000, the work surface can reach 10,000, equipped with mobile runner and adjustable jack, flexible to adapt to changing working positions.

$ 1442.00

The double outlet design can pRoduce UP water and RO water at the same time, the water pRoduction capacity is 10L/H, the resistivity of UP water is > 10MΩ · cm@25 ℃, and the fully enclosed pipeline design and automatic timing flushing function are adopted to ensure the stability of water quality.

$ 767.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
Superhydrophobic surface coating is applied to the microstructure substrate using a film coating machine.
This article introduces the coating process of superhydrophobic surface coatings on microstructured substrates. Superhydrophobic coatings feature high water contact angles and low rolling angles, making them widely used in applications such as anti-fouling and waterproofing.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.