The three-in-one optical path measures the transmittance of three wavelengths at one time, the test aperture is 1mm to adapt to small-sized materials, and the parallel light design ensures stable measurement of thick materials, with an accuracy of +/- 2% and a resolution of 0.1%.
Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.
The minimum test aperture is 0.5mm, and the three Illuminants share a test hole. Three transmittance data of 550nm, 850nm and 940nm can be obtained for one hole. Real-time dynamic self-Adjustment, Test accuracy +/- 2%.
It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.
Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.
Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.
Using 3-in-1 optical path design, one hole can simultaneously measure three wavelengths transmittance. Equipped with 1mm test aperture and Automatic calibration function, support 850nm/940nm infrared and 550nm visible light measurement, accuracy of +/- 2%.
The three Illuminants share a test hole, and the 380nm-760nm visible light, 940nm infrared and 365nm ultraviolet transmittance can be obtained in one measurement. The parallel light design can test large thickness materials, and the 1mm test aperture is suitable for small size samples.
The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.
It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.
Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.
Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.
Adopt LED Illuminant to achieve 0~ 100% measurement range, resolution up to 0.1, support single continuous measurement mode, lightweight structure only 100g, can be through USB/RS-232/Bluetooth multi-mode data transmission.
Optical inspection components imported, measurement range 0.0-99%, accuracy ≤ 2%, with single and continuous two measurement modes, support MAX Maximum, MIN Minimum, average statistics, can store 800 sets of data and connect to computer communication.
Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.