Rapid Isothermal Test Chamber

The rapid isothermal test chamber maintains a constant internal temperature through electric heating and refrigeration systems, enabling samples to quickly reach a stable state at the set temperature. It is used to simulate the performance changes of materials in specific temperature environments, making it suitable for testing processes such as paint curing and plastic aging.
Selection
When selecting, consider that the temperature range covers the testing needs, the temperature control accuracy meets standard requirements, the chamber volume accommodates the sample size, the heating and cooling rates align with the experimental cycle, the equipment materials are corrosion-resistant and easy to clean, and operational stability has been verified through practical testing.

Instruments

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.

$ 25973.00

Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.

$ 9836.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and the PID adaptive algorithm is equipped to ensure that the Temperature Uniformity is ≤ 2 ° C, and the 512L studio meets the diverse testing requirements.

$ 31347.00

Using multi-channel mechanical compression refrigeration system and frequency conversion technology, energy consumption is reduced by 20%; with a linear temperature rise and fall rate of 15 ° C/min, Temperature Uniformity ≤ 2 ° C; through forced air duct system and special PID algorithm to achieve rapid temperature convergence and stability control.

$ 15210.00

Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve rapid temperature change of 5 ° C/min; equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, support 120 groups of program editing and remote monitoring functions.

$ 20599.00

With a linear temperature rise and fall rate of 10 ° C/min and a wide temperature range of -60 to 150 ° C, multi-channel refrigeration system and PID adaptive algorithm are used to achieve rapid temperature convergence, and environmentally friendly refrigerants and low noise design are equipped.

$ 18437.00

Multi-channel mechanical compression refrigeration system and adaptive throttling technology are used to achieve 5 ° C/min linear temperature rise and drop and +/- 0.5 ° C Temperature Fluctuation; equipped with PID adaptive algorithm and forced air duct system to ensure temperature uniformity and rapid convergence.

$ 15210.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure Temperature Uniformity ≤ 2 ° C, with remote monitoring function.

$ 28119.00

Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.

$ 13064.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, reduce energy consumption and noise through frequency conversion technology, and support 120 sets of program editing and remote monitoring functions.

$ 28119.00

Using multi-channel mechanical compression refrigeration system, energy saving up to 80% of congeneric pRoducts; with 5 ℃/min rapid temperature change rate; through forced air duct system to ensure Temperature Uniformity ≤ 2 ℃; equipped with remote monitoring and fault self-diagnosis function.

$ 15210.00

Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.

$ 196.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and is equipped with a two-stage throttling system and a forced air duct to ensure temperature uniformity ≤ 2 ° C. Remote visual control and fault self-diagnosis functions are supported through RS485 communication.

$ 20599.00

Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.

$ 196.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00