Infrared Thermal Imaging Microscope

Infrared thermal imaging microscopes generate thermal distribution images by detecting the infrared radiation emitted by samples, revealing temperature differences on the surface of materials. They are used to observe the thermal behavior of materials such as plastics and coatings, as well as to analyze localized heating or defects.
Selection
When selecting, consider the temperature range and resolution to match sample requirements, and pay attention to detection sensitivity and imaging speed. Choose lens specifications based on sample size, and ensure software compatibility for analytical functions. Evaluate environmental adaptability, such as anti-vibration design.

Terms

Standards

Instruments

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.

$ 339.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.

$ 138.00

Temperature resolution is up to 0.1 ℃, heating rate is adjustable from 0.1 ℃ to 20 ℃/min, hot stage method and visual measurement are supported, which is suitable for the study of thermal characteristics of trace samples.

$ 4600.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Illuminant lighting can continuously adjust the luminance, equipped with swing Abbe condenser and four-hole converter, support 5 million pixel CMOS imaging and geometric measurement analysis functions to meet a variety of observation needs.

$ 2941.00

Made of aluminum, Dimension 150 * 220 * 290mm, support 360 ° swirl/spin adjustment and arm adjustable, suitable for a variety of Microscope models.

$ 154.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.