Chemical Paint Viscosity Tester

The chemical paint viscosity tester calculates viscosity by measuring the resistance encountered by a rotor rotating in the sample. It is used to monitor the fluidity and application performance of coatings, and is applied in paint production, quality control, and adjustments to coating processes.
Selection
Select the instrument with the corresponding range based on the sample viscosity, match the rotor type according to the material characteristics, determine the portable or benchtop structure based on the operating environment, choose an economical model for routine testing, and perform regular calibration and maintenance using standard oil.

Terms

Standards

Instruments

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure Spreader uniformity and test accuracy.

$ 391.00

Using film lamination technology, with 0.29mm paper Film thickness and surface Laminating, providing uniform film Spreader and solvent chemical resistance, easy hiding power, Opacity test.

$ 618.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure accurate and reliable test results.

$ 635.00

Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.

$ 244.00

Using film lamination technology, it has excellent solvent and chemical resistance, ensuring uniform film Spreader, paper Film thickness 0.29mm, surface Laminating enhanced durability, suitable for a variety of test environments.

$ 443.00

Using film lamination treatment, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and surface Laminating to ensure Spreader uniformity and test accuracy.

$ 635.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent, ensure Spreader uniformity and with annotation section for easy recording.

$ 509.00

Using film lamination technology, with excellent solvent resistance and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent, Laminating surface to ensure Spreader uniformity.

$ 356.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Laminating surface design, Film thickness 0.29mm, no fluorescent whitening agent, solvent resistance and chemical resistance, Laminating uniform and with annotation section for easy recording of test information.

$ 259.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm, surface Laminating to ensure Spreader uniformity, with annotation section for easy recording of test data.

$ 306.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

Spreader uniformity is ensured by film lamination technology, with 0.29mm paper Film thickness and solvent resistance, and each cardboard has a dedicated annotation area for recording test data.

$ 388.00

Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.

$ 167.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.