Temperature Cycling Shock Chamber

The high-low temperature cyclic shock test chamber subjects samples to rapid temperature changes by quickly switching between high-temperature and low-temperature chambers. This equipment simulates the extreme temperature variations that products may encounter during transportation, storage, or usage, and is used to test material properties such as thermal expansion and contraction, coating adhesion, and the reliability of electronic component solder joints. In the coatings industry, it can verify the crack resistance of paint films, while in the plastics industry, it tests the deformation coefficient of products.
Selection
When selecting, ensure the temperature range covers the practical application limits, with a common standard being -40℃ to +150℃. The temperature change rate affects the severity of the test, typically requiring 15℃ per minute or higher. Allow one-third extra volume in the chamber based on the sample dimensions. Pay attention to the corrosion resistance of the sample racks and the anti-frost feature of the observation window. The compressor brand relates to cooling stability, and the control system should have fault logging capability. Verify the availability of a third-party calibration certificate.

Terms

Standards

Instruments

The static test is realized by the Three-Box structure air path switching method, with a maximum impact time of 999 hours and a cycle period of 9999 times. It is equipped with a binary refrigeration system for rapid cooling, and supports automatic cycling or manual selective impact.

$ 12139.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and air passage switching system to achieve fast and stable Thermal Shock testing.

$ 36381.00

The three-box structure design is adopted, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, the Thermal Shock test is realized through the air circuit switching, and the touch graphic operation interface is equipped to simplify the operation process.

$ 16759.00

Adopting a three-box structure design, the temperature recovery time does not exceed 5 minutes, and the temperature conversion is completed within 10 seconds. It is equipped with a touch-sensitive graphic operation interface and an air path switching system to achieve fast and stable Thermal Shock testing.

$ 12660.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.

$ 17985.00

Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.

$ 7771.00

Temperature range -30~ 150 ℃ and Temperature Uniformity ≤ +/- 2 ℃, using multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector and solid state relay control to ensure stable operation.

$ 7948.00

Articles