Fixed Combustible %LEL Detector

Fixed combustible gas detectors monitor the concentration of combustible gases in the environment through sensors and trigger an alarm when the concentration exceeds a preset threshold. They are used for continuous monitoring in locations such as chemical plants and oil depots to prevent safety accidents caused by gas leaks.
Selection
When selecting, consider the types of gases to be detected, the measurement range, explosion-proof rating, and environmental adaptability. Confirm the sensor lifespan and calibration cycle, check that the signal output method is compatible with the existing system, and assess the coverage requirements for the installation location.

Terms

Instruments

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and infrared remote control operation, through a number of international safety certifications.

$ 190.00

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, support 4-20mA and RS485 output, with flameproof structure and remote alarm function.

$ 383.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, with flameproof structure and multi-signal output, support remote monitoring and customized Sensor.

$ 202.00

It adopts flameproof structure design, supports 4-20mA, RS485 and switch output, Response Time ≤ 30 seconds, Detection error ≤ +/- 3% F.S. It can be operated by remote control without opening the lid, with sound and light alarm function, suitable for dangerous environment gas monitoring.

$ 254.00

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and linkage control.

$ 190.00

Using infrared NDIR detection principle, range 0-5% Vol, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote monitoring capability.

$ 332.00

Supports simultaneous detection of four gases and temperature Humidity, adopts dual temperature Humidity compensation design, has zero point automatic correction function, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 301.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with infrared remote control debugging and 4~ 20mA output, support alarm record query and automatic temperature compensation, suitable for hazardous environment.

$ 152.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, support 4~ 20mA and RS485 output, infrared remote control safety adjustment.

$ 122.00

Using catalytic combustion Sensor, range 0~ 100% LEL, with automatic zero correction and temperature compensation function, support infrared remote control adjustment and 4~ 20mA standard output, suitable for dangerous places 1 and 2 zones.

$ 135.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, Response Time does not exceed 60 seconds, support 4~ 20mA and RS485 output.

$ 135.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation functions, support 4~ 20mA output and infrared remote control debugging, suitable for dangerous areas 1 and 2 zones.

$ 143.00

Designed with explosion-proof and explosion-proof structure, Response Time is less than 30 seconds, Maximum power consumption is 3W, Support 4-20mA standard signal output, High Accuracy and stable performance, Suitable for a variety of industrial environments.

$ 267.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00