VOC sensor

VOC sensors detect changes in the concentration of volatile organic compounds in the air, converting chemical signals into electrical signals for output. They are used in environmental monitoring, industrial safety, and other fields to provide real-time information on the levels of organic compounds in the air.
Selection
When selecting a VOC sensor, it is essential to consider that the detection range aligns with the target substances, the response speed meets the requirements of the application scenario, the anti-interference capability handles complex environments, the service life matches the maintenance cycle, and the output signal is compatible with existing equipment.

Terms

Standards

Instruments

Using PID Sensor technology, range 0~ 500ppm, resolution 0.1ppm, support 1-6 Sensor expansion, with a variety of signal output modes, including 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for harsh environments.

$ 1818.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Using ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³, equipped with independent variable frequency wind speed adjustment device, Modular design is easy to maintain, and the operating power is as low as 1.2kw.

$ 25602.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Pump-suction sampling and PID photoion technology, detection accuracy of +/- 3%, Response Time ≤ 20 seconds, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 1532.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Adopt PID light ion detection principle, range 0-50ppm, Response Time ≤ 30S, with explosion-proof structure, multiple signal output and remote alarm function, support customized wireless transmission.

$ 1171.00

Adopt PID photoion detection principle, range 0-50ppm, Response Time ≤ 30S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 1171.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

Adopt air jacket indirect temperature control to avoid condensation, dry moisture ratio control humidity Response fast, background concentration as low as formaldehyde ≤ 0.006mg/m ³, support automatic temperature control and humidity control and multiple safety protection, suitable for material environmental protection assessment.

$ 26699.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Dart impact tester measures the toughness of packaging film.
The dart impact test evaluates the material's resistance to damage under dynamic impact, i.e., its toughness, by allowing a dart to fall freely and strike the packaging film. During the test, different impact energies are simulated by adjusting the weight of the dart or the drop height, and sensors are used to detect whether the film ruptures.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.