High-temperature Thermal Indicator Patch

High-temperature temperature indicating strips are based on thermosensitive materials that undergo color or morphological changes at specific temperatures, with temperature determined by comparing against a standard color chart. They are used to monitor the surface temperature of objects and are suitable for high-temperature environments such as ovens and welding.
Selection
When selecting, consider that the temperature measurement range covers actual needs, the response time matches the process speed, the size and shape are suitable for the measured surface, pay attention to the temperature resistance of the adhesive, and confirm that the accuracy meets the process requirements.

Terms

Standards

Instruments

Irreversible discoloration design to ensure permanent preservation of temperature records, 85 ° C accurate temperature measurement point with 2x2cm circular patch, Pressure sensitive adhesive layer to achieve firm paste and its own protective film to enhance durability

$ 89.00

70 ℃ rated temperature monitoring, irreversible discoloration characteristics ensure the accuracy of temperature recording, 40 * 40mm square patch design for easy installation and observation, reflective display function supports all-weather monitoring.

$ 81.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Using irreversible color change, it features 60°C and 80°C temperature monitoring, rectangular temperature grid design, and reflective display for easy detection of temperature anomalies at night.

$ 80.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

When the temperature reaches 90 ° C, the patch changes from white to black, with irreversible discoloration characteristics; the reflective display function is convenient for day and night inspection to detect temperature abnormalities, with a size of 25 * 21mm.

$ 81.00

Using irreversible discoloration technology, white turns black after overheating and displays numbers at the same time. Measuring temperature 80 ° C, diaMeter 2 cm circular patch design, suitable for indoor environment use.

$ 88.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.

$ 91.00

Using triple-channel thermal insulation structure, the damper switching time is completed within 10 seconds, and the temperature recovery time is within 5 minutes. With 96 test specification settings, the maximum Impact time is 9999 minutes, meeting the needs of high and low temperature rapid change testing.

$ 27829.00

Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.

$ 16372.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Measuring temperature 90 ℃ and the error is only +/- 1 ℃, the melting state can be observed at a distance, directly pasted and used to visually display the overheating of the equipment.

$ 89.00

Adopting three-color reversible discoloration technology, when the temperature reaches 75 ° C, it turns from white to red, and turns black when it falls back to record the over-temperature history. The size is 25 * 21mm, with stickers for easy installation, and the repeability can be used to monitor temperature changes.

$ 86.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Temperature Paper Selection: Temperature Gradation and Response Speed Evaluation
This article mainly discusses how to choose the right temperature measurement paper. It points out that two key parameters should be considered during selection: the temperature steps and the response speed.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.