Molecular microscope

Molecular microscopes scan sample surfaces with electron beams, detect reflected electron signals to form images, and are used to observe the microscopic morphology and composition distribution of materials. In the coatings and inks industry, they are employed to analyze pigment dispersion and coating structures.
Selection
Select vacuum or environmental mode based on the sample's conductivity, choose the electron gun type according to resolution requirements, incorporate energy spectrum attachments for elemental analysis, consider the sample chamber size to accommodate materials of varying thickness, and ensure the operating environment meets laboratory conditions.

Terms

Standards

Instruments

Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.

$ 339.00

Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.

$ 138.00

Made of aluminum, Dimension 150 * 220 * 290mm, support 360 ° swirl/spin adjustment and arm adjustable, suitable for a variety of Microscope models.

$ 154.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Microscope observation mode, support capillary method and hot table method, temperature range RT +~ 320 ℃, resolution 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), Draft Shield design to reduce environmental impact.

$ 749.00

Using binocular stereo Microscope observation, support capillary method and hot table method two measurement methods, temperature resolution of 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), with Draft Shield to reduce environmental impact.

$ 875.00

Equipped with 0.7-4 times high definition industrial grade continuous zoom Microscope, the three-dimensional movement accuracy of the stage reaches 0.01mm, supports video recording and automatic titration function, can observe and test from multiple angles, and data export is convenient.

$ 5802.00

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

The water pRoduction rate reaches 10L/h, the water intake Flow velocity is 1.0L/min, and the RO membrane intelligent anti-scale washing and automatic domestic circulation system are used to ensure stable water quality and meet the high standard requirements of the laboratory.

$ 2300.00

The water pRoduction rate is 10L/h, and the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, providing 18.25MΩ. cm ultra-pure water quality, supporting multiple water intake modes and intelligent control functions.

$ 4027.00

With 20~ 200 times magnification, equipped with 8 adjustable luminance LED lights, support 2 million pixel image interpolation to 5 million pixels, easy to observe surface fine structure.

$ 678.00

The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.

$ 3543.00

With 450-600X manual adjustment magnification, support microscopic photography, video recording and calibration measurement functions, small size only 12cm long, built-in 8 adjustable warm white light, suitable for mobile detection environment.

$ 393.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

Articles

Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Differential Scanning Calorimetry measures the heat of curing reaction of thermosetting polymers.
Differential scanning calorimetry is a commonly used technique for studying the curing reactions of thermosetting polymers. It measures the heat released by a sample during heating to obtain key parameters such as reaction enthalpy and curing temperature.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Differential Scanning Calorimetry for Measuring the Degree of Cure of Polymer Optical Waveguide Materials
This article introduces a method for determining the degree of curing in polymer optical waveguide materials using a differential scanning calorimeter. The degree of curing is a key indicator affecting material performance, and this instrument quantitatively analyzes it by measuring the thermal effects during the curing reaction.
The film applicator applies hydrocolloid adhesive onto medical dressings.
The coating machine is used to apply a hydrocolloid adhesive evenly onto the substrate of medical dressings. This adhesive, made from hydrophilic polymer materials, maintains its adhesion and comfort in moist environments.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
UV aging test chambers are used for the aging evaluation of polymer materials.
The UV aging test chamber accelerates the aging process of polymer materials by simulating ultraviolet radiation from sunlight, combined with temperature and humidity control, to evaluate their durability.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.
Application of Tensile Testing Machines in Polymer Materials
A tensile testing machine is a device used to test the mechanical properties of materials by stretching specimens and measuring force and deformation, thereby evaluating the toughness of materials such as plastics and rubber.