Electromagnetic Film Thickness Gauge

The electromagnetic film thickness gauge generates an alternating magnetic field through its probe, inducing eddy currents in the metal substrate. The intensity of the eddy currents varies with the thickness of the non-conductive coating, and the instrument calculates the film thickness accordingly. It is used to measure the thickness of coatings such as paint, plastic, and ceramic on metal surfaces to ensure the quality of the coating application.

Instruments

Using electromagnetic induction principle to achieve nondestructive detection, measurement range of 0-9500μm, accuracy +/- 3%. With continuous single double measurement mode, automatic identification of substrate material, support 2000 sets of data storage and four statistical functions.

$ 344.00

Using electromagnetic induction principle to achieve 0-5000μm measurement range, equipped with alloy integration Probe and temperature compensation technology, support continuous single two measurement mode, can store 2000 sets of data and have automatic substrate identification function.

$ 267.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.

$ 127.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.

$ 186.00

The principle of electromagnetic induction is used for measurement of nonmagnetic coatings, with a maximum thickness of 6000 μm and a resolution of 0.1 μm. It has IP65 Protection Rating and fast measurement capability of more than 180 readings per minute.

$ 1542.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Using mechanical measurement method, Measurement range 0~ 1mm, accuracy ≤ 0.005mm, Graduation 0.001mm, probe diaMeter Φ 5mm, suitable for flat film and sheet, providing two probe pressure options.

$ 267.00

Measurement range 0-2000μm, error +/- 3%, with continuous and single test mode, can store 2000 sets of data and support computer connection communication.

$ 235.00

Measurement range 0-1500μm, error +/- (3% + 1.5μm), continuous and single Measurement mode, can store 2000 sets of data and support computer communication.

$ 173.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.