Cyclic Electric Oven

The circulating electric oven heats air through electric heating elements and uses a fan to circulate the hot air inside the chamber, achieving uniform heating. It is used for sample drying, heat treatment, material curing, and other laboratory and industrial processes to ensure temperature distribution consistency.
Selection
When selecting a circulating electric oven, consider matching the temperature range with sample requirements, ensuring the chamber size accommodates sample capacity, meeting experimental needs with temperature control accuracy, the impact of fan performance on uniformity, corrosion resistance of materials, safety features such as over-temperature protection, as well as energy consumption and maintenance costs.

Terms

Standards

Instruments

Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.

$ 5307.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Adopt electric push Rod to drive Spreader movement, adjustable speed range of 2-200mm/s, temperature accuracy +/- 3 ℃, support Vacuum chuck and electric heating function, improve Spreader uniformity and operation convenience.

$ 2494.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, temperature control accuracy +/- 1 ℃, support 0-9999 minutes timing and remote monitoring function.

$ 791.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, support 0.1 ℃ temperature resolution and 0-9999 minutes timing function, to ensure the experimental environment stable and reliable.

$ 1192.00

Temperature control accuracy of +/- 1 ℃, equipped with intelligent digital display and observation window, Inner Chamber dimensions 350 * 450 * 450mm, electric heating tube heating to ensure uniform and stable temperature.

$ 393.00

With a 45 ° test angle and an adjustable speed of 5mm/sec, equipped with a 500g weight and a standard pencil set, stable and low-noise electric control is achieved through a stepper motor.

$ 477.00

Temperature range -60~ 130 ℃, humidity control 30~ 95% RH, non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 7377.00

Equipped with PID microcomputer intelligent temperature control system, Temperature Fluctuation +/- 1 ℃, temperature resolution 0.1 ℃; The studio is made of mirror stainless steel, Shelf spacing is adjustable, and the bottom heating hood quick-release structure is easy to clean.

$ 780.00

Using microcomputer intelligent PID control technology, Temperature range RT + 5~ 250 ℃, Temperature Fluctuation +/- 1%. External hot air circulation system ensures stable temperature, adjustable studio shelf spacing, easy access to different specifications of samples.

$ 340.00

Temperature control accuracy of +/- 1.0 ℃, temperature resolution of 0.1 ℃, equipped with double-decked tempered Glass observation window and quick-release bottom heating hood, easy to clean and maintain, two heating power to meet different temperature needs.

$ 590.00

Rotation speed of 10000rpm is achieved by using 750W three-phase asynchronous motor, and the electric lifting platform supports 300mm Travel, which can handle 10L materials and work continuously for a long time.

$ 1284.00

Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with independent temperature controller, hot air circulation system consists of low noise fan and air duct, indoor shelf height and quantity can be adjusted.

$ 343.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.