Digital Thickness Indicator

The digital thickness gauge measures material thickness by using a probe to contact the surface, converting mechanical displacement into an electrical signal, and displaying the thickness value digitally. It is used for measuring the thickness of coatings, films, plates, and other materials, ensuring product specifications are met during quality inspection and production control.
Selection
When selecting a digital thickness gauge, it is essential to consider whether the measurement range covers the sample thickness, the accuracy meets tolerance requirements, the probe type is compatible with the material characteristics, the calibration method complies with standards, the operating environment suits on-site conditions, and the data output functionality matches recording needs.

Terms

Standards

Instruments

With 0.001mm High Accuracy and 1.0μm resolution, low pin pressure design and digital linear encoder, it supports multiple international standards for thickness measurement of various sheet substrates.

$ 20768.00

Measurement range 0-4mm, contact pressure 100kPa, contact area 2cm ², equipped with digital dial Meter to achieve accurate thickness measurement.

$ 688.00

Measurement range 0~ 12.7mm, accuracy ≤ 0.02mm, using digital display reading indexing value 0.01mm, simple structure and reliable mass.

$ 477.00

Measurement range 0-4mm, contact pressure 100kPa, equipped with dial indicator mechanism, can achieve accurate thickness detection, suitable for a variety of sheet materials.

$ 535.00

Adopt wear-resistant ruby Probe, measurement range 0~ 1250μm, error +/- 2~ 3%, built-in LED indicator light, IP65 dustproof and waterproof, chemical resistant, suitable for industrial environment.

$ 856.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

Irreversible discoloration design to ensure permanent preservation of temperature records, 85 ° C accurate temperature measurement point with 2x2cm circular patch, Pressure sensitive adhesive layer to achieve firm paste and its own protective film to enhance durability

$ 89.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.

$ 91.00

Using digital High Accuracy dial head, Measurement range 0~ 12mm, Graduation up to 0.01/0 mm, with measurement safety locking mechanism and holding function, easy and reliable operation.

$ 286.00

Adopt wear-resistant ruby Probe, measurement range 0~ 3000μm, error +/- 2~ 3%, IP65 Protection Rating, chemical-resistant material, suitable for chemical cleaning, built-in LED indicator light to facilitate over-limit detection.

$ 959.00

Measuring temperature 90 ℃ and the error is only +/- 1 ℃, the melting state can be observed at a distance, directly pasted and used to visually display the overheating of the equipment.

$ 89.00

Measurement range 0-20mm, accuracy 0.01mm, contact pressure 20 +/- 0.5kPa, contact surface diaMeter 35.7mm, suitable for a variety of sheet material thickness detection, to ensure high parallelism and Precision.

$ 493.00

It is designed with a digital thousand-minute differentiator, with a dual unit display of μm and mils, with a range of 0~ 10mm and a Graduation of 1μm, to achieve precise thickness control.

$ 154.00

Adopt double roller painting film structure, thickness adjustment range 0.001-2mm, Spreader accuracy +/- 5%, equipped with automatic deviation correction device and digital dial Meter, coating speed 0-20m/min adjustable, drying tunnel temperature up to 150 ℃.

$ 32347.00

Measurement range 0-6mm, accuracy of 0.01mm, contact pressure 100 +/- 5kpa, with digital display function and stable parallelism measurement, suitable for a variety of materials Film thickness detection.

$ 382.00

Articles

Preparation of composite films by coating mechanism for electrical performance experimental characterization
This article introduces the method of preparing composite films using a film coating machine and testing their electrical properties. The film coating machine evenly spreads the slurry with a blade, controlling thickness and uniformity. The preparation process includes raw material preparation, substrate treatment, coating, and curing.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Method for Determining the Reference Plane in the Measurement of Coating Thickness on Rough Substrates
This article primarily discusses how to determine the reference plane when measuring coating thickness on rough substrates. Due to the undulations of rough surfaces, the interface between the coating and the substrate is unclear, making it difficult to measure accurately using traditional methods.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
Film Coating Machine vs. Spray Gun: The Impact of Different Coating Methods on Coating Performance Evaluation
This article compares two laboratory film preparation methods: the film applicator and the spray gun. The film applicator can produce coatings with uniform thickness and high reproducibility through blade coating, making it suitable for precise formulation studies. The spray gun simulates actual spraying, but the film thickness uniformity is poorer, and the surface may be rougher.
Application of Sand Abrasion Tester in the Coatings Industry
The sand falling abrasion tester evaluates the wear resistance of coatings by allowing standard abrasives to fall from a fixed height to impact the coating surface and measuring the amount of abrasive required to wear away a certain thickness.
Choosing a laboratory coating machine for phase change material thin film coating is more professional.
Phase change material thin films have important applications in areas such as thermal energy management, and their performance is influenced by factors such as thickness uniformity and surface morphology. Laboratory research and development require precise control of parameters like coating speed and temperature to ensure the stability of the material's phase change characteristics.
Detailed Explanation of Laboratory Vacuum Adsorption Platform: Flatness is the Cornerstone of Successful Coating
The vacuum adsorption platform is a key device in coating experiments, which stabilizes the substrate by negative pressure adsorption, providing a reference plane for coating. The flatness of the platform surface is crucial, as even minor deviations can lead to defects such as uneven coating thickness or the appearance of streaks.
The working principle of laboratory wire rod coaters and methods for controlling coating thickness
The laboratory wire rod coater is a precision instrument used to prepare uniform, thickness-controllable wet film coatings on substrate surfaces. Its core components include a coating rod, a flat coating platform, clamps for securing the substrate, and a mechanical system that drives the coating rod to move at a constant speed.