Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Parallel light path design can measure 100mm thickness material, accuracy +/- 1%, resolution of 0.001%, support field and fixed station two Measurement mode, suitable for a variety of Optical inspection material detection.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Imported linear slide rail to ensure parallel accuracy 0.1 +/- 0.01mm, blade Hardness can be cut steel, sampling thickness 0~ 5mm, special treatment die durable and easy to restore accuracy.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.
Based on the principle of flow between parallel plates, it can quickly and accurately measure inks spread under low shear stress. The sample volume is 0.5 +/- 0.003 cubic centiMeters, and the maximum measurement range of the plate is 9cm. It is suitable for inks flowability evaluation.
The device places the test plate in parallel in the wind tunnel, the wind speed control accuracy is 3 +/- 0.3m/s, the drying time is automatically controlled, and the surface crazing can be visually inspected, which is suitable for the evaluation of coating anti-crack performance.
The device provides 3 +/- 0.3m/s wind speed through axial flow fan in wind tunnel, Timer delay range of 0.01 seconds to 99 hours 99 minutes, can automatically control drying time and eye test plate surface crazing, support parallel test.
The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.
The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.
The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.
The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.
The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.