Electric Temperature Detection Color-changing Sticker

Electric temperature detection color-changing stickers utilize thermochromic materials that change color at specific temperatures, allowing for visual comparison to determine the surface temperature of the object being measured. They are used for monitoring equipment operation status, providing early warning for circuit board overheating, and other applications, enabling temperature monitoring without the need for a power source.
Selection
When selecting, it is necessary to match the working temperature of the measured object with the color-changing threshold of the patch, confirm the adhesion between the patch substrate material and the object surface, consider the impact of environmental humidity and chemical corrosion, check the need for color change reversibility, and verify whether the color-changing response time and accuracy meet the monitoring requirements.

Terms

Standards

Instruments

Using irreversible color change, it features 60°C and 80°C temperature monitoring, rectangular temperature grid design, and reflective display for easy detection of temperature anomalies at night.

$ 80.00

Irreversible discoloration design, the temperature window from white to red is clearly recognizable, with oil-proof and waterproof protective film, the back sticker is easy to paste, can be stored for 2-3 years, each 120 pieces size 12x30mm.

$ 150.00

With unique discoloration and digital display function, it can change white to red, red to black three Color changes, temperature monitoring range of 75 ℃, can record over temperature history, with its own sticker for easy installation and use.

$ 86.00

Immediate Temperature Response with Irreversible Color Changing Technology, Measurement accuracy +/- 1 ° C to +/- 4 ° C, Resistant to Oil, Water and Steam, Provides Long-term Temperature Record for Easy Paste and Preservation.

$ 96.00

Using electric pressure system, the printing pressure is adjustable from 0 to 2mm, the speed range is 0 to 80 Meters, low accuracy overprinting is supported, and the computer program control operation is stable.

$ 5915.00

Adopt irreversible color changing technology, accuracy +/- 1-4 ° C, oil and water resistance and steam resistance, provide four-grid temperature monitoring, size 23x45mm, 10 sheets each, easy to record temperature history for a long time.

$ 93.00

Using electric pressure system and circular pressing operation mode, printing pressure 0-4mm, speed 0-100 Meters, adjustable scraper pressure and speed, support low accuracy overprinting and Color detection.

$ 6020.00

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

Irreversible discoloration records the temperature. When the temperature is exceeded, the window is obviously visible from white to red. It has an oil-proof and waterproof protective film and a adhesive backing for easy pasting. Each sheet is 120 pieces, and the shelf life is 2-3 years.

$ 150.00

With 5 temperature monitoring points, Temperature range 77 ° C to 99 ° C, irreversible discoloration record, oil and water resistance, BS EN ISO 9001 compliant, with a sticker on the back for easy installation.

$ 92.00

Temperature range of 50~ 120 ℃, irreversible discoloration, over-temperature grid window from white to red, clear contrast, suitable for indoor and outdoor equipment temperature display.

$ 140.00

Single point temperature monitoring, permanent discoloration irreversible after overheating, specification 2.5x4 cm, with anti-fouling protective film, indoor service life of 3 years, outdoor 2 years.

$ 89.00

Adopt electric push Rod to drive Spreader movement, adjustable speed range of 2-200mm/s, temperature accuracy +/- 3 ℃, support Vacuum chuck and electric heating function, improve Spreader uniformity and operation convenience.

$ 2494.00

It can simultaneously print color bars of different Colors or Ink Film thickness, detect inks Hue and Gloss, uniform ink time can be adjusted from 1 to 800 seconds, support dry and wet ink discoloration analysis and abrasion resistance testing.

$ 4367.00

Adopting irreversible discoloration technology, when the temperature exceeds 70 ° C, it turns from white to black and displays numbers. The size is 60 * 8mm rectangular design, which is convenient for inspection to find temperature abnormalities and prevent failures.

$ 85.00

Articles

How should one choose between the blade coating method and the spin coating method for perovskite film deposition experiments?
In the fabrication of perovskite solar cells, spin coating and blade coating are two commonly used film deposition methods, each with its applicable scenarios.
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.