Box-Type Muffle Furnace

The box-type muffle furnace generates high temperatures through resistance heating elements, and the furnace chamber uses insulation materials to maintain uniform heat distribution. It is used for sample ashing, melting, and heat treatment, as well as for conducting heat resistance tests on materials such as coatings and plastics in laboratories.
Selection
When selecting a box-type muffle furnace, considerations should include the maximum temperature and uniformity, matching the furnace chamber volume to the sample size, ensuring temperature control accuracy meets standard requirements, selecting materials with corrosion resistance suitable for the substances being processed, and confirming that energy consumption and safety protections are appropriate for the operating environment.

Terms

Standards

Instruments

The maximum temperature can reach 1200 ℃, Furnace volume 7L, using microcomputer PID controller precise temperature control, refractory brick Furnace durable, Furnace door sealing design to enhance Temperature uniformity, safe and simple operation.

$ 1145.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.

$ 1046.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

With 30 stages of multi-stage programmable control, the highest temperature 1200 ℃, Furnace volume 7L, using refractory brick Furnace and nickel-chromium wire heating elements, heat loss is small and Temperature uniformity is good.

$ 1392.00

Adopt 30-segment programmable controller to achieve automatic temperature control, Furnace volume 2L, maximum temperature 1000 ℃, equipped with stainless steel liner and ceramic fiber Furnace, with excellent thermal insulation and Temperature uniformity, and integrated multiple Safety protection system.

$ 1263.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

Maximum temperature up to 1200 ℃, Furnace volume 16L, microcomputer PID control to ensure accurate and stable temperature, unique Furnace door design to enhance sealing to reduce heat loss, refractory brick Furnace and nickel-chrome wire heating elements to provide long-term durability.

$ 1460.00

The refractory brick Furnace has excellent thermal insulation performance, is equipped with 50-stage program temperature control system, Temperature Fluctuation +/- 2 ℃, supports over-temperature alarm and timing function, and the Furnace volume is 7.2L to ensure the safety and stability of the experiment.

$ 1009.00

Using wirecoil for heater heating components and refractory brick Furnace, the maximum temperature is 1000 ℃, the Furnace volume is 2L, with multiple Safety protection measures such as overcurrent, overpressure and overheating.

$ 740.00

Use refractory brick Furnace and good wirecoil for heater heating, maximum temperature 1000 ℃, Power 4KW, with intelligent PID control and multiple Safety protection to ensure uniform heating and operation safety.

$ 938.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the refractory brick Furnace and the unique Furnace door design, the heat loss is small and the temperature is uniform, with a variety of Safety protection measures.

$ 1430.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.