Low-temperature cooling liquid circulator

The low-temperature coolant circulator uses a compressor to cool the coolant and circulate it to external equipment, removing heat and maintaining a low-temperature environment. It is used for constant-temperature cooling of laboratory equipment such as reaction vessels and spectrometers, ensuring stable experimental conditions.
Selection
When selecting, consider that the temperature range should cover experimental requirements, the cooling power should match the equipment's heat output, the pump flow rate should meet circulation needs, the tank size should be compatible with the equipment to be cooled, and pay attention to the freezing point and corrosion resistance of the coolant.

Terms

Standards

Instruments

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Two-stage Compressor refrigeration combined with maintenance-free pressure suction pump, maximum Flow rate 22L/min, pressure 1bar, resistant to fiber and metal particles, adapt to external load automatic adjustment, effectively protect external equipment.

$ 1632.00

The double Compressor cascade refrigeration system is adopted, with fast cooling and low noise, Temperature Fluctuation +/- 0.05 ° C, and pump Flow rate of 8L/min to ensure the uniformity of liquid in the Tank and reliable operation.

$ 1368.00

Using environmental refrigerant R134a, the cooling time is reduced by more than 40%, Temperature range -40~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, support multi-stage programming and independent temperature limit alarm, easy to operate and clean.

$ 3462.00

Adopting PID digital control technology implementation +/- 0.1 ℃ temperature fluctuation, fluorine-free refrigeration system has high refrigeration efficiency, is equipped with adjustable Flow rate pump and large open liquid Tank, supports internal and external circulation.

$ 2817.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

The use of non-heat centrifugal circulation pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, support 200 degrees of high temperature directly start cooling, domestic circulation system to achieve a high degree of uniformity in the flow field, to ensure a stable liquid environment.

$ 6902.00

Double Compressor cascade refrigeration system is used to achieve rapid cooling, Tank volume 6L with 8L/min pump Flow rate to ensure liquid uniformity, Temperature Fluctuation control within +/- 0.05 ℃, Precision Pt100 Sensor to ensure long-term stable operation.

$ 2203.00

Adopt non-heat centrifugal circulation pump to avoid its own heat pRoduction, Temperature Uniformity +/- 0.05 ℃, support 200 degrees high temperature direct start cooling without damaging the Compressor, equipped with 13L/min external circulation Flow rate to ensure stable insulation field.

$ 2671.00

Temperature range covers -50 to 200 ° C, supports 200 ° C direct start cooling without damaging the Compressor; uses a heat-free centrifugal circulation pump and U-shaped return design to ensure Temperature Uniformity +/- 0.05 ° C; provides a variety of Safety protection such as low water level and temperature runaway alarm.

$ 2044.00

The use of non-heat centrifugal circulation pump to avoid its own heat effect temperature field, Temperature Uniformity of +/- 0.05 ℃, at 200 degrees high temperature can directly start the Compressor refrigeration, to ensure the stable operation of the equipment.

$ 3030.00

Using fluorine-free refrigeration system, Compressor refrigeration can be started directly at a high temperature of 200 ° C. Temperature Uniformity up to +/- 0.05 ° C, equipped with a 13L/min high Flow rate circulating pump, to achieve a high uniformity of the flow field in the Tank.

$ 4751.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.