Ozone Sterilization Oven

The ozone sterilization oven generates ozone through corona discharge, utilizing its strong oxidizing properties to destroy the microbial cell structure, thereby achieving sterilization within an enclosed space. Combined with a heating system that accelerates ozone decomposition and dries items, it is suitable for surface sterilization of ozone-resistant materials such as laboratory glassware and medical instruments.
Selection
When selecting, ensure that the ozone concentration inside the chamber can reach the sterilization threshold, and the inner chamber material must be corrosion-resistant. Determine the volume based on the size of the items to be processed, and pay attention to temperature uniformity and the ozone residual decomposition device. It is necessary to match the on-site power supply conditions and verify the equipment’s safety certifications and protective measures.

Terms

Standards

Instruments

Adopt silent ozone generator and UltravioletDetector, ozone concentration control accuracy +/- 2pphm, support static tensile and dynamic tensile test, Temperature Uniformity ≤ 2 ℃ to meet a variety of test conditions

$ 8529.00

Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.

$ 11079.00

Imported stainless steel liner and independent ozone concentration controller, temperature control accuracy of +/- 0.5 ℃, equipped with static tensile fixture and rotational speed adjustable sample rack, support long-term stable operation.

$ 10643.00

High Accuracy PID control technology, temperature fluctuation +/- 0.5 ℃, equipped with independent ozone concentration controller long-term stable non-drift, support static tensile specimen and program operation mode.

$ 13128.00

SUS304 stainless steel inner box and double insulation structure, equipped with 360 degree swirl/spin sample holder and precise ozone concentration control, temperature fluctuation +/- 0.5 ℃, support static dynamic tensile test, suitable for rubber durability research.

$ 5899.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 12015.00

Using UV absorption principle to detect ozone, range 0-2.00 mg/L can be selected to 20.00mg/L, accuracy error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support flameproof design and a variety of signal output, suitable for complex industrial environment.

$ 1364.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 16017.00

With 0~ 100ppm ozone detection range and T90 ≤ national standard Response Time, support remote paraMeter configuration and zero automatic correction, explosion-proof IP66 protection is suitable for harsh industrial environments.

$ 716.00

Equipped with ultraviolet sterilization system to effectively prevent pollution, temperature control accuracy of +/- 0.3 ℃, support multi-stage programming and independent temperature limit alarm, to ensure the safety and stability of the experiment.

$ 943.00

Microcomputer intelligent control ensures precise temperature control, Temperature Fluctuation +/- 0.5 ℃ and uniformity up to 1 ℃. Equipped with UV sterilization function and stainless steel liner, support low temperature compensation, volume 300L to meet the diverse needs of foster.

$ 1226.00

With UV sterilization function to reduce the risk of contamination, Power 12-1200W is continuously adjustable, supports 0.2-500 ml crush capacity, can store 20 sets of programs and realize remote monitoring.

$ 3535.00

With UV sterilization function to reduce the risk of cross contamination, Power 10-1000W is continuously adjustable, supports 0.1-700 ml crush capacity, can store 20 sets of programs and realize electric lifting operation.

$ 3010.00

Using professional refrigeration technology implementation 5-50 ℃ wide range of temperature control, temperature uniformity up to 1 ℃; equipped with ultraviolet sterilization lamp can be directly observed foster, stainless steel liner to ensure long-term use without corrosion.

$ 1146.00

With UV sterilization function to reduce the risk of cross-contamination, Power 18-1800W continuously adjustable, crushing capacity 1-1200ml, support remote control and electric lifting, flexible and convenient operation.

$ 4059.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?