Thickness MicroMeter Gauge

Thickness micrometers utilize a mechanical contact measurement principle, where a precision screw mechanism drives the probe to contact the sample surface, allowing direct reading of the thickness value from the dial. They are used for thickness inspection of materials such as films, coatings, and paper, enabling rapid testing in both production sites and laboratories.
Selection
When selecting, consider that the measurement range should cover the sample thickness, the precision should meet the process requirements, and the probe size should be compatible with the shape of the object being measured. Contact pressure must avoid material deformation, and environmental temperature should not affect measurement stability. Prioritize the use of gauges with calibration certificates and regularly verify measurement accuracy with standard blocks.

Terms

Instruments

The weight load constant cutting force is used for automatic cutting, and the cutting is automatically stopped after completion. MicroMeter device can adjust the thickness of the sample cutting to achieve precision cutting. Spindle Rotation speed is adjustable from 50 to 800rpm, equipped with a chill down system to avoid sample burns, and the surface is bright and flat after cutting.

$ 2789.00

With 0.001mm High Accuracy and 1.0μm resolution, low pin pressure design and digital linear encoder, it supports multiple international standards for thickness measurement of various sheet substrates.

$ 20768.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

With emission-echo and echo-echo two thickness measurement modes, Measurement range 0.65~ 600mm, Probe type can be automatically identified and zero point calibrated, support anti-measurement Speed of sound function to improve accuracy.

$ 667.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Measurement of nonmagnetic coatings on ferrous metals, thickness range 0-6000μm, accuracy +/- 3%, built-in Probe single-handed operation, Protection Rating IP65, 60 + readings per minute.

$ 1022.00

Measurement range 1.2~ 225mm, support Speed of sound measurement and 12 data storage functions, with upper and lower limit alarm settings and coupling status prompts, suitable for a variety of material thickness detection.

$ 223.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

Using microprocessor technology implementation 0.7-400 mm thickness measurement, resolution is +/- 0.01mm, support five Probe options, with automatic shutdown and backlight display function.

$ 577.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Measurement range with 0.01mm high resolution and 0.65-400 mm width supports Probe automatic identification and multiple Measurement modes, which can penetrate the thickness of the coating measurement substrate and realize the data freezing display.

$ 1610.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Articles

Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
The correct method for using a wet film thickness gauge.
The wet film thickness gauge is used to measure the thickness of uncured coatings. It determines the value by reading the scale through contact with the wet film using a toothed structure, which is crucial for controlling dry film thickness and estimating material usage.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
The role of the coating machine in the preparation of fuel cell membrane electrode assemblies
The film coating machine is a key equipment for preparing the membrane electrode, the core component of fuel cells. It evenly coats a catalyst-containing slurry onto a substrate using techniques such as blade coating, slot-die extrusion, or spraying, forming a catalytic layer ranging from a few micrometers to several tens of micrometers in thickness.