Portable particulate matter Detector

The portable particulate matter detector measures the quantity and particle size distribution of suspended particles in the air through the principle of laser scattering. It is used for on-site rapid monitoring of dust concentration and is suitable for particulate matter pollution assessment in areas such as workshop environments and spray painting operations.
Selection
When selecting, pay attention to whether the detection particle size range covers PM2.5/PM10, ensure the sampling flow rate is stable, the housing protection rating is suitable for the on-site environment, the data storage function meets recording requirements, the calibration cycle aligns with usage frequency, and the sensor lifespan and maintenance costs fit within the budget.

Terms

Standards

Instruments

High Accuracy Electromagnetic Force equilibrate Sensor, Readability up to 0.1mg, Support solid, liquid and particulate matter (PM) density measurement, Built-in RS232 interface for easy data recording, Ensure measurement results Repeatability and accuracy.

$ 412.00

KF25 joint diaMeter, filtrate diaMeter ≥ 25um particulate matter (PM), yellow filter can be cleaned or replaced in time, suitable for pumping speed ≤ 6L/s Vacuumpump, slightly affect pumping speed and Vacuum Level.

$ 143.00

Measurement range 0-500mg/L, accuracy 1mg/L, Repeatability 3%, support AC and DC power supply and automatic shutdown, suitable for a variety of liquid suspended matter detection.

$ 304.00

Using laser scattering technology, a single measurement can simultaneously display up to five particle size particulate matter (PM) concentrations, Sensitivity of 0.001 mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.

$ 4398.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Measurement range 0.00~ 14.00, accuracy +/- 0.05, Stability +/- 0.03, support 0~ 60 ℃ temperature compensation, portable and lightweight only 205g, suitable for a variety of environments.

$ 156.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Using light scattering principle, detection sensitivity of 0.01mg/m ³, Measurement range 0.01-100 mg/m ³, with self-calibration system and air curtain Shielding function, 1 minute can directly read the mass concentration results, support timing sampling and over-standard alarm.

$ 1655.00

Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.

$ 144.00

Conductivity Detector measurement principle, measurement range 0~ 84%, accuracy +/- 0.5%, Response Time 1 second, with temperature and humidity compensation technology, portable design weight only 265 grams, suitable for on-site rapid detection.

$ 160.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Detection of oxygen concentration 0~ 25% range, resolution of 0.1%, Response Time ≤ 15 seconds, Portable design, suitable for a variety of environment monitoring needs.

$ 162.00

Conductivity Detector Measurement principle, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time only 1 second, with temperature and humidity compensation technology, probe Sensor can be deeply measured inside the material, support multi-gear design and Interface customization.

$ 267.00

Measurement principle using Conductivity Detector method, Measurement range 8~ 40%, accuracy +/- 0.5%, with automatic compensation function of Temperature and Humidity, Response Time is only 1 second, Portable design weight about 203 grams, suitable for on-site rapid detection.

$ 264.00

Instantaneous Response Time Less than 6 seconds warm-up, can detect 3 g/year Sensitivity halogen refrigerant, 405 g lightweight design with 5 hours continuous Working time, with automatic warm-up and two-color LED charge indication function.

$ 140.00