Resistance-Based Moisture Determination Device

The resistive moisture meter determines moisture content by measuring changes in the electrical resistance of the material. Variations in moisture levels cause corresponding changes in resistance, which the instrument detects and converts into moisture readings. It is used for rapid moisture detection in solid materials such as paper, grains, and wood.
Selection
Select the corresponding electrode model based on the type of material being tested. Consider the moisture measurement range and accuracy requirements. Pay attention to the influence of material temperature on the measurement. Check the instrument calibration method and stability. Confirm that the electrode protection rating is suitable for the operating environment.

Terms

Standards

Instruments

Suitable for Coulometry moisture determination, containing 500mL KF-1A Reagent and 5 bottles of 5mL KF-1B Reagent, supporting a variety of Moisture Meters to meet the needs of laboratory moisture analysis.

$ 236.00

Imported chips ensure stable performance, 1 second Fast Response to complete the detection, measurement range 10-85%, resolution of 0.1%, suitable for all kinds of fresh meat moisture determination.

$ 225.00

Using halogen radiation heating technology, the moisture readability reaches 0.01%, the determination of Precision +/- 0.2%, and the test is completed quickly in a few minutes, with 8 kinds of paraMeter display functions.

$ 446.00

Using Coulomb ElectRode technology, it can measure 10μg~ 20mg moisture, support 10mA to 100mA electrolysis current, no need to calibrate Reagent, with RS232 interface to connect to the printer.

$ 1939.00

Using halogen lamp heating source, temperature adjustment accuracy +/- 0.1 ℃, moisture readability 0.02%~ 0.1%, support timing automatic end measurement, ensure stable and efficient measurement.

$ 477.00

Measurement principle using resistance method, Measurement range 2~ 70%, accuracy +/- 2%, Response Time only 1 second. With 4 wood Measurement modes, support Data storage and voice reminder function.

$ 94.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

It is suitable for volumetric moisture determination, including 500mL of A and B Reagents, with a titration range of 3-5, and is used with ZDY-502/ZDY-504 instruments.

$ 204.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, the portable and lightweight is only 203 grams, suitable for on-site rapid detection.

$ 138.00

Measurement range 0-99.9%, Response Time 1 second, Multi-gear selection and 50mm scanning depth, suitable for on-site rapid moisture determination.

$ 223.00

Using 300W solar bulbs and hot air circulation heating, Temperature range RT +~ 120 ℃, can accurately control the test conditions, determination of material under light yellowing resistance performance, suitable for a variety of shoe material testing.

$ 1719.00

Fast heating with halogen lamp, temperature control accuracy +/- 0.1 ℃, moisture measurement range 0-100%, readability of 0.02% -0.1%, support 9 display paraMeters and RS232 communication interface to meet the needs of multi-sample testing.

$ 509.00

Supports iron-based and non-iron-based material measurement with accuracy of +/- 1~ 3% or +/- 2.5 µm, provides split Probe for enhanced maneuverability, automatically recognizes matrix materials and remembers calibrated values.

$ 527.00

Measurement principle using resistance method, accuracy of 0.1%, support a variety of grain Measurement range, with voice reminder and automatic shutdown function, portable design weighs only 254g.

$ 90.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, 25 kinds of special gears for grain, the integrated design is easy to carry, and the Response Time is only 1 second.

$ 165.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.