Electrically Powered Incubator

The electric incubator maintains a constant temperature environment through electric heating and temperature control systems, and is used for microbial and cell culture as well as constant-temperature storage of samples. It is commonly found in laboratory biological testing and material aging tests.

Instruments

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Integrated Incubator and Shaker functions, small footprint and large bottle capacity; Microcomputer PID control temperature and Oscillation Frequency, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner is easy to clean, supports multi-stage programming and UV sterilization to ensure safe and efficient operation.

$ 1773.00

Mirror stainless steel liner is easy to clean, Temperature range 15~ 45 ℃, Temperature Fluctuation +/- 0.5 ℃, three speed fan to avoid sample volatilization, with independent temperature limit alarm system to ensure safety.

$ 2150.00

Temperature control accuracy of +/- 0.3 ℃, equipped with ultraviolet sterilization system to prevent pollution, support multi-stage programming and independent temperature limit alarm to ensure experimental safety and uniformity, suitable for long-term foster needs.

$ 3107.00

Mirror stainless steel studio easy to clean, Temperature range 0-65 ℃ accuracy +/- 0.5 ℃, equipped with UV sterilization lamp and ultrasonic humidifier, support 1-9999 minutes timing function.

$ 2203.00

Equipped with ultraviolet sterilization system to effectively prevent pollution, temperature control accuracy of +/- 0.3 ℃, support multi-stage programming and independent temperature limit alarm, to ensure the safety and stability of the experiment.

$ 943.00

Unique air duct structure to ensure temperature uniformity +/- 1 ℃, microcomputer intelligent temperature control accuracy of +/- 0.5 ℃, equipped with auxiliary thermostat and leakage protection, liner made of stainless steel for easy cleaning, optional ultraviolet sterilization system.

$ 711.00

The cavity preheating technology implementation of uniform temperature distribution, with the forced convection system to shorten the temperature recovery time. Temperature Uniformity +/- 0.5 ℃, volume 130L, equipped with multiple over-temperature protection and adjustable shelf design.

$ 1216.00

Using fluorine-free refrigeration technology, Temperature range 0~ 60 ℃, Temperature Uniformity +/- 1.5 ℃, equipped with mirror stainless steel liner and microcomputer intelligent temperature control system, support 1-9999 minutes timing function.

$ 877.00

The mirror stainless steel liner is used for easy cleaning, Temperature Fluctuation is only +/- 0.2 ℃, the circulating wind speed is automatically adjusted to avoid sample volatilization, and 7 sets of programs can be preset by supporting multi-stage programming control.

$ 1053.00

Microcomputer intelligent temperature controller, Temperature Fluctuation +/- 0.5 ℃, Temperature Uniformity +/- 1 ℃, duct structure to ensure uniform temperature, liner arc design for easy cleaning, optional ultraviolet sterilization and remote control interface.

$ 554.00

Adopting a fluorine-free refrigeration design, the cooling time is reduced by more than 40% compared to traditional equipment, and the temperature fluctuation is controlled within +/- 0.5 ° C. It is equipped with an ultraviolet sterilization system to effectively prevent pollution and support remote monitoring.

$ 880.00

The mirror stainless steel liner is easy to clean, Temperature range 0~ 60 ℃ and fluctuation +/- 0.5 ℃, three wind speed adjustment to avoid sample volatilization, with independent temperature limit alarm system to ensure safe operation of the experiment.

$ 990.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.