Temperature range -20~ 20 ℃, cooling capacity up to 1800W, cooling time is reduced by 35% compared with traditional equipment, open Bath can be applied to acid solution and organic solution thermostatic experiment.
Integrated Air-Cooled circulation device, cooling capacity 3600W, temperature control range of 5~ 35 ℃, with water shortage, temperature, water pressure and overheating and overcurrent multiple Safety protection functions.
Using environmental refrigerant R134a, the cooling time is reduced by more than 40%, Temperature range -40~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, support multi-stage programming and independent temperature limit alarm, easy to operate and clean.
Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.
The double outlet design can pRoduce UP water and RO water at the same time, the water pRoduction capacity is 10L/H, the resistivity of UP water is > 10MΩ · cm@25 ℃, and the fully enclosed pipeline design and automatic timing flushing function are adopted to ensure the stability of water quality.
The double water outlet design can provide both UP and RO water simultaneously, with a water pRoduction capacity of 20L/H, a fully enclosed pipeline to maintain stable water quality, automatic timing flushing and water shortage protection functions, and quiet operation with noise below 40 decibels.
With penetrating AISI 316 stainless steel Probe, easy to clean and insert semi-solid pRoducts. With CAL Check ™ boot self-check function, temperature accuracy of +/- 0.2 ℃, Measurement range covering -50.0~ 220 ℃.
7-Inch color touch screen control, three-way water quality online monitoring of incoming water, RO water, and UP water, with a water pRoduction capacity of 60L/H, an effluent resistivity greater than 18.25MΩ · cm, and support for quantitative water intake and one-click disinfection.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety protections such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
With 40L/H water pRoduction capacity and 18MΩ · cm resistivity ultrapure water output, the 7-inch touchscreen displays three-way water quality and temperature in real time, supports automatic circulation, consumables reminder and disinfection functions, ensuring stable water quality and low bacterial contamination.
Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.