Air-Exchanged Thermal Shock Chamber

The air-exchange thermal shock test chamber subjects samples to rapid temperature changes by quickly switching between high-temperature and low-temperature airflows. It is used to test the tolerance of materials under sudden temperature variations and is commonly employed in temperature resistance testing for electronic components, coatings, plastics, and other products.
Selection
When selecting an air-cooled thermal shock test chamber, factors to consider include the temperature range, transition time, chamber volume, and sample load capacity. The temperature range should cover the testing requirements, a short transition time can simulate rapid temperature shocks, the chamber volume should match the sample size, and the load capacity should ensure testing stability.

Terms

Instruments

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.

$ 17985.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and air passage switching system to achieve fast and stable Thermal Shock testing.

$ 36381.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

The three-box structure design is adopted, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, the Thermal Shock test is realized through the air circuit switching, and the touch graphic operation interface is equipped to simplify the operation process.

$ 16759.00

Adopting a three-box structure design, the temperature recovery time does not exceed 5 minutes, and the temperature conversion is completed within 10 seconds. It is equipped with a touch-sensitive graphic operation interface and an air path switching system to achieve fast and stable Thermal Shock testing.

$ 12660.00

The three-box structure is used to achieve static test, the temperature conversion time is ≤ 10 seconds, the temperature recovery is ≤ 5 minutes, the air passage switching mode intRoduces the temperature, and the temperature control accuracy is +/- 0.5 ℃, which is suitable for material thermal expansion and contraction testing.

$ 17275.00

The three-box structure realizes the separation of the high temperature zone, the low temperature zone and the test zone, the air passage switching mode intRoduces the temperature for Impact, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the microcomputer equilibrate temperature control system and the double-stage Compressor chill down.

$ 10240.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time can reach 9999 minutes. With 96 test specification settings and P.I.D automatic calculation control to ensure Test accuracy.

$ 20228.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.

$ 22019.00

The three-box heat storage structure is used to realize forced air circuit switching, the temperature recovery time is less than or equal to 5 minutes, and the conversion only takes 10 seconds. With independent temperature control in high temperature zone, low temperature zone and test zone, it can perform 2-box or 3-box Impact mode to meet different test needs.

$ 17759.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.