Impedance of PHY Glass film less than 500MΩ, with porous PTFE liquid complex and silver ion trap reference system, support 0~ 130 ℃ wide temperature measurement, Response is fast and stain resistance is strong.
The PHY Glass membrane is used to withstand strong acid and alkali corrosion, and the membrane Impedance is less than 500MΩ to ensure the measurement Stability; the porous PTFE liquid complex and 3M KCl gel electrolysis solution are designed to improve the anti-pollution performance, suitable for 0-130 ℃ high temperature environment.
Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.
Temperature range + 5 to 200 ° C, pump flow up to 15L, provides High Accuracy, uniform temperature and controlled constant field source for a variety of experimental environments.
Suitable for the measurement of high alkaline samples, using circular Glass sensitive film and porous abrasive liquid interface, pH Measurement range 0~ 14, Permissible Ambient Temperature 0~ 100 ℃, providing stable reference potential.
Fluorine-free environmental Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and porous U-shaped domestic circulation system to ensure stable and uniform temperature.
Using double-sided uniform tin plating process, the surface mass reaches class I, Hardness is T52, standard thickness is 0.28mm, to ensure accurate and reliable film test results.
Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.
Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.
Using non-fluorine environmental protection Compressor refrigeration system, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and porous U-shaped domestic circulation design, to ensure that the flow field temperature field is highly uniform.
With 0-100 ℃ precise temperature control and 200-1800rpm oscillation function, metal module to avoid pollution, support multi-point operation and timing settings, DC brushless motor drive maintenance-free.
Using the isokinetic sampling theory, the wind speed of the sampling head is consistent with the air speed of the clean room. Sampling flow rate is 100L/min, which can work continuously for 10 hours. All 316 stainless steel materials ensure the accuracy and durability of collection.
Metal module to avoid sample contamination, temperature control accuracy of +/- 0.5 ℃, speed range of 200-1800rpm, support multi-point operation and power failure automatic recovery function.
Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.
32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.