Low-temperature Furnace

The low-temperature furnace heats up via electric heating elements and maintains the set temperature with the assistance of a temperature control system. It is used for heat treatment, drying, or curing of materials in low-temperature environments and is commonly applied in laboratory settings such as paint curing and plastic aging tests.
Selection
When selecting, consider that the temperature range must cover experimental requirements, and pay attention to the heating rate and temperature control accuracy. Determine the furnace volume based on sample size and check the data on heating uniformity. Pay attention to safety protection functions and energy consumption indicators, and evaluate the durability of the equipment in conjunction with the budget.

Terms

Standards

Instruments

Using double-decked shell structure and aluminum oxide Furnace material, temperature control accuracy +/- 1 ℃, heating rate ≤ 20 ℃/min, temperature field Balance and energy saving, low surface temperature.

$ 6948.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

The highest temperature is 1400 ℃, the Furnace volume is 4.5L, and the aluminum oxide fiber Furnace and silicon carbon Rod heating elements are used to support the inert gas environment and ensure the uniform and stable sintering of the material.

$ 3720.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

Operating temperature up to 1700 ℃, Furnace volume 80L, aluminum oxide fiber Furnace and double chill down system, support inert and reducing atmosphere environment material sintering treatment.

$ 7867.00

Using ceramic fiber Furnace and air insulation structure, the surface temperature is only about 50 ℃. Heating to 1200 ℃ for less than 25 minutes, temperature control accuracy +/- 1 ℃, support multi-step program control.

$ 2048.00

The refractory brick Furnace has excellent thermal insulation performance, is equipped with 50-stage program temperature control system, Temperature Fluctuation +/- 2 ℃, supports over-temperature alarm and timing function, and the Furnace volume is 7.2L to ensure the safety and stability of the experiment.

$ 1009.00

The maximum temperature is 1200 ℃, the Furnace volume is 80L, and the temperature rise to 1200 ℃ is less than 25 minutes. Ceramic fiber insulation material is used, the surface temperature is low, the temperature control accuracy is +/- 1 ℃, and it has multi-step temperature control function, and the temperature fluctuation is small.

$ 3467.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

The maximum temperature can reach 1200 ℃, Furnace volume 7L, using microcomputer PID controller precise temperature control, refractory brick Furnace durable, Furnace door sealing design to enhance Temperature uniformity, safe and simple operation.

$ 1145.00

The double-decked Furnace shell insulation design is adopted, and the shell is not hot; the Furnace temperature distribution uniformity is less than +/- 5 ° C, and the heating rate is ≥ 10 ° C/min; it has a nitrogen filling device to slow down oxidation and supports flexible setting of self-made temperature control programs.

$ 1019.00

Imported HRE ultra-high temperature alloy heating element, heating to 1200 ℃ less than 25 minutes, temperature control accuracy +/- 1 ℃, Furnace body and shell with air insulation structure, low surface temperature.

$ 1303.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Muffle Furnace Ash Test Method for Determination of Inorganic Filler Residues in Varnish
This article introduces the method of using the muffle furnace ash test to determine the residual amount of inorganic fillers in varnish. The inorganic substances in varnish can affect the performance of the coating, making accurate determination of ash content important for quality control.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.