Rod-type Thermometer

The rod-type thermometer detects the temperature of an object through a thermal sensor at the front end of the metal rod, converting temperature changes into electrical signals to display numerical values. It is used for measuring the internal temperature of liquids, granules, or soft materials, and is commonly applied in food processing, chemical engineering, and storage industries.
Selection
When selecting, consider that the temperature measurement range covers usage needs, the rod material's corrosion resistance matches the measurement environment, the probe length adapts to the depth of the measured object, the response speed meets operational frequency, and the display accuracy aligns with practical application tolerances.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.

$ 104.00

The photoelectric counter is used to realize automatic counting, and the measurement is fast and accurate; the period of M-3 swing Rod is 0.625s, and the swing time on standard Glass is 440 +/- 6s; the horizontal mechanism is improved, and the scale can be moved horizontally to facilitate zero adjustment.

$ 451.00

Film speeds are adjustable from 1 to 150mm/s for A4 size charts. Equipped with replaceable Glass or perforated vacuum beds, compatible with standard block and spiral bar film applicators, Operating interface is simple and intuitive.

$ 6637.00

The highest temperature is 1300 ℃, the Furnace volume is 4L, the silicon carbide Rod heating element is resistant to high temperature and oxidation, the microcomputer PID control is accurate and reliable, and has multiple Safety protection measures.

$ 1934.00

Using silicon carbon Rod double-sided heating technology, rapid heating and high thermal efficiency; Temperature range 300~ 1300 ℃, Temperature Fluctuation +/- 5% ℃, with PID microcomputer system to ensure accurate and stable temperature, with over-rise alarm and menu lock and other safety functions.

$ 909.00

Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.

$ 180.00

Using silicon molybdenum Rod heating element and double-decked air-cooled structure, the maximum temperature is 1700 ° C, the heating rate is 10 ° C/min, with 30-stage program temperature control and +/- 1 ° C thermostatic accuracy, and the Furnace shell surface is kept at low temperature to ensure safe operation.

$ 10482.00

Using silicon molybdenum Rod heating element and double-decked air-cooled structure, the maximum temperature is 1800 ° C, thermostatic accuracy +/- 1 ° C, with 30-stage program temperature control and rapid temperature rise and drop function, the Furnace shell surface is kept low temperature to ensure safe operation.

$ 7174.00

With a wide temperature measurement range from -200 ° C to 1371 ° C, accuracy up to +/- 0.5 ° C, support Manual calibration and RS232 Interface, waterproof design to ensure stable operation in humid environments.

$ 632.00

Waterproof design ensures safe use in humid environment, supports three Thermocouple Probe types, Measurement accuracy up to +/- 0.5 ℃, dual measurement interface can connect two Probes at the same time, equipped with data locking and temperature Unit switching function.

$ 749.00

Adapted diaMeter 16mm formed Metering Rod, the total length of 2000mm, through the special structure to correct the straightness of the Rod body, to ensure stable rotation and full contact with the substrate, improve the thickness control accuracy of Spreader.

$ 590.00

Using silicon carbide Rod double-sided heating, rapid heating and high thermal efficiency; maximum temperature 1200 ℃, temperature control accuracy +/- 5% ℃; PID microcomputer control combined with K-type Thermocouple, temperature accuracy and stability.

$ 1119.00

Silicon carbon Rod double-sided heating to achieve rapid heating, 70 minutes up to 1300 ℃; PID control combined with K-type Thermocouple to ensure +/- 5% temperature accuracy; closed aluminum silicate Furnace with optional exhaust device to improve thermal efficiency and safety.

$ 909.00

Dual Probe design can measure two samples at the same time, equipped with BEPS low power error prevention system to avoid wrong readings, Measurement accuracy of +/- 0.5 ℃, support K/J/T type multiple temperature sensors, waterproof design to adapt to complex environments.

$ 528.00

When stirring, tangential flow is generated, turbulence is small, heat exchange performance is good, slurry diaMeter 100mm, Rod length 400mm, suitable for medium and low speed use, mild stirring performance.

$ 110.00

Articles

Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Actual Coating Thickness Deviation of Stainless Steel Wire Rod Coaters at Different Slurry Solid Contents
This article analyzes the actual coating thickness deviation of stainless steel wire rod coaters under different slurry solid contents. The study finds that the solid content of the slurry affects its viscosity and flowability, leading to deviations in the actual coating thickness from the theoretical value.
Testing principle of the mandrel bending method for paint film flexibility tester
The shaft-rod bending method is a common technique for testing the flexibility of paint films. It involves bending a test panel coated with the paint film over shafts of different diameters to simulate the deformation of the coating under stress.
Paint Flexibility Tester for Measuring Bending Adaptability
The coating flexibility tester is a device used to assess whether a coating cracks or peels when bent. During testing, the coated sample is bent around mandrels of different diameters, and the surface condition is examined. The flexibility is evaluated based on the smallest mandrel diameter at which no cracking occurs.
The determination of the yield value of ink using a falling bar viscometer.
This article introduces the method of measuring the yield value of ink using a falling rod viscometer. The yield value refers to the minimum stress required for the ink to start flowing, which is crucial for print quality.
Cone Bend Test Evaluates the Ultimate Deformation of High-Elasticity Coatings
This article introduces the use of a conical mandrel bend test to evaluate the ultimate deformation capacity of highly elastic coatings. The test involves bending a coated sample around a conical mandrel of specific diameters and observing the minimum mandrel diameter at which the coating cracks or peels off, thereby assessing the material's ability to withstand deformation.
Coating film preparation techniques: comparison between wire-wound applicators and wet film preparators
This article compares two commonly used tools in laboratory coating film preparation: the wire rod coater and the wet film applicator.
The laboratory coating machine easily coats various aqueous and oily slurries.
The laboratory film applicator is a precision instrument used to prepare uniform coatings on substrates, primarily operating on the principle of a blade or wire-wound rod. It allows adjustment of parameters such as speed and pressure to control coating thickness.
How to achieve high uniformity in silver nanowire transparent conductive films through wire rod coating
This article introduces how to prepare uniform silver nanowire transparent conductive films using the wire rod coating technique. These films, which use silver nanowires as the conductive material, exhibit high transparency and conductivity, making them suitable for applications such as touch panels.
Common Troubleshooting for Wire Bar Coater: Solving Issues of Streaking and Uneven Thickness
This article mainly introduces solutions to two common faults in the operation of the wire rod coater—coating streaks and uneven coating thickness.
Blade Coating VS Wire Rod Coating: The Precision Battle and Selection Guide in the Lab
Blade coating and wire bar coating are two commonly used physical coating methods in laboratories. When selecting between them, factors such as material properties, target thickness, and experimental conditions must be considered. Both methods have their own advantages and can be flexibly chosen or used to validate each other based on specific requirements.
Application of Wire Bar Coater in the Preparation of Coating, Ink, and Printing Samples
A wire-wound rod coater is a laboratory tool used for preparing uniform wet film coatings on flat substrates, widely applied in the production of samples in the coatings, inks, and printing industries.