With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.
With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.
Using high-resolution video camera technology to replace the traditional Microscope, the temperature range is from room temperature to 350 ° C, and 4 samples can be processed simultaneously, compatible with powder and block sample measurement. Temperature resolution reaches 0.1 ° C.
Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.
Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.
Adopting the test principle of inclined rolling ball method, the tilt angle adjustment range is 0~ 40 °, equipped with 32 GCr15 bearing steel balls, and the shape tolerance accuracy exceeds GB/T308 level 40 to achieve accurate initial Tack evaluation.
Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.
Humidity environment can be simulated according to the national standard design, with 500g measuring device and 1cm ² flat bottom area, easy to operate and accurate results.
Equipped with 1000g weight and 1~ 999999 minute Timer, using SUS #304 steel plate to ensure test accuracy and meet a number of national standards.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.