Film Damp Heat Alternating Test Chamber

The film damp heat alternating test chamber simulates alternating environments of high temperature and high humidity with low temperature and dryness through a temperature and humidity control system, causing materials to generate physical stress under cyclic changes. It is used to detect performance changes such as expansion, deformation, and aging of materials like film under damp heat alternating conditions. It is commonly applied in durability testing for photosensitive materials and packaging materials.
Selection
When selecting, ensure the temperature and humidity range covers the actual usage environment, with fluctuations controlled within ±0.5℃ and ±2% RH. The inner chamber should be made of corrosion-resistant stainless steel and equipped with a visual observation window and test ports. The compressor must meet rapid temperature change requirements, and the programming should support multi-segment cyclic settings. Confirm compliance with basic standards such as GB/T2423.

Standards

Instruments

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.

$ 1663.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Adopt double cylinder synchronous circuit and upper and lower heat seal independent temperature control, Heat seal Temperature range RT +~ 300 ℃, Temperature control accuracy +/- 1 ℃, support manual and pedal two start modes, heating head with protective cover to ensure safety.

$ 1300.00

Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.

$ 1413.00

Using stainless steel mirror liner and French Taikang Compressor, temperature range -60~ 150 ℃, Fluctuation ≤ +/- 0.5 ℃, equipped with large screen Touchscreen and multiple safety protection system, high test accuracy and stable and reliable.

$ 7222.00

Temperature range -70~ 150 ℃, Temperature Uniformity +/- 2 ℃, using multi-layer conductive film observation window and upper air supply and lower air return system, support 120 sets of program settings and continuous PID control, with multiple safety protection mechanisms.

$ 8093.00

Adopt stainless steel mirror liner and A3 steel plate spray shell, equipped with 7 inch Touchscreen control instrument, Temperature Fluctuation ≤ +/- 0.5 ℃, uniformity ≤ +/- 2 ℃, support -20~ 150 ℃ wide temperature range test, with PID automatic calculation function.

$ 9481.00

The heat sealing paraMeters are determined by hot pressing sealing method, the temperature control accuracy is +/- 0.1 ℃, the heat sealing temperature can reach 300 ℃, and the upper and lower heat sealing heads have independent temperature control and manual foot pedal dual start mode, which is safe and anti-scalding design.

$ 2110.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

Temperature range -30~ 150 ℃, studio volume 800L, multi-layer conductive film observation window and independent over-temperature protector, with 120 sets of program settings and continuous PID control function.

$ 10336.00

Temperature range -30~ 150 ℃, studio volume 500L, using multi-layer conductive film observation window and PID continuous control, with 120 sets of program settings and multiple safety protection systems to ensure stable and reliable testing.

$ 8900.00