Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.
Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.
The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.
Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.
Adopt stainless steel air duct and centrifugal fan, the wind speed is adjustable, the dust concentration is 2.0~ 4.0kg/m ³, support vertical circulation and dust drying, ensure test uniformity and data accuracy.
Adopting stainless steel air duct and centrifugal fan, the wind speed can be adjusted, the dust concentration is 2.0~ 4.0kg/m ³, and it has the function of vertical circulation air flow and dust drying to ensure the accuracy and uniform dispersion of test data.
Adopt stainless steel air duct and centrifugal fan, dust concentration 2.0~ 4.0kg/m ³, liner size 1000 * 1500 * 1000mm, support vertical circulation air flow and dust drying function, ensure accurate and reliable test data.
Volume 800L, Temperature range 4-50 ℃, light intensity 0-30000LX, support 30 sets of program settings, with independent temperature limit alarm system and mirror stainless steel liner design.
Adopt stainless steel air duct and vertical circulation air flow system, equipped with frequency converter to adjust the wind speed, dust concentration 2.0~ 4.0kg/m ³, built-in vibration and drying device to ensure the accuracy of test data.
With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.
Adopt stainless steel air duct and centrifugal fan, talc concentration 2.0~ 4.0kg/m ³, support dust drying and vibration function, ensure test data accuracy and uniform dispersion.
Using refractive index Measurement principle, automatic temperature compensation 0-40 ℃, Measurement time of about 1.5 seconds, only 100 μ L sample volume, support PSU, ppt and specific gravity three unit conversion, stainless steel sample Chamber corrosion resistance.