Separatory Funnel Vertical Shaker

The separatory funnel vertical shaker uses a motor to drive the vertical reciprocating motion of the funnel holder, ensuring thorough mixing of the liquid and solvent inside the funnel. It is used for operations such as liquid-liquid extraction and sample pretreatment in the laboratory.
Selection
When selecting, consider the oscillation frequency range, load capacity, timing function, fixture compatibility, and operational stability, matching parameters based on common separatory funnel specifications and experimental requirements.

Terms

Standards

Instruments

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

Vertical oscillation mode with 280rpm frequency, smooth operation and low noise, stainless steel spring universal fixture, can be adapted to a variety of test bottles, to meet a variety of mixing needs.

$ 356.00

With vertical oscillation mode, Oscillation Frequency up to 280rpm, pendulum amplitude of 20mm, smooth operation and low noise, stepless speed regulation can be flexibly adjusted, stainless steel spring fixture is suitable for a variety of test bottles.

$ 393.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

The horizontal and vertical combined oscillation mode is adopted, and any mode can be used alone. The stepless speed regulation range starts to 300 times/min, and the pendulum amplitude is 20mm, which has the characteristics of low noise and long life.

$ 490.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

DC brushless motor and horizontal circumference swirl/spin mode, swirl/spin frequency 60-250rpm, swing amplitude 28mm, with slow start and uniform acceleration function to prevent liquid splashing, support static foster.

$ 5866.00

Integrated Incubator and Shaker functions, small footprint and large bottle capacity; Microcomputer PID control temperature and Oscillation Frequency, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner is easy to clean, supports multi-stage programming and UV sterilization to ensure safe and efficient operation.

$ 1773.00

Frequency range starts to 300 times/minute stepless speed regulation, swing amplitude 20mm, low noise and low power consumption, suitable for a variety of experimental environments.

$ 451.00

The fixture can fix the upper and lower ends of the butterfly specimen into a vertical shape, test the vertical compression strength, suitable for a variety of Corrugated Board types, Dimension 150 * 105 * 65mm, weight about 2Kg, easy to operate.

$ 596.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Support forward and reverse rewinding and unwinding functions, with tension control and deviation correction functions, vertical mesh running speed 1mm/s to 1m/min, effective coating area 1500 * 600mm, to ensure that the mesh vertical stability without shaking.

$ 14274.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Standard Operating Procedure for Packaging Drop Tester
The packaging drop tester is used to evaluate the impact resistance of transport packages during vertical drops. Before operation, it is necessary to check the safety of the equipment, calibrate the drop height, and prepare the test specimens according to standards.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Pull-off adhesion tester quantitatively measures bond strength.
The pull-off adhesion tester measures the bonding strength between coatings, linings, and substrates by applying a vertical tensile force.
Pull-off testing for interlayer adhesion of multilayer coating systems.
This article introduces the pull-off method for testing the interlayer adhesion of multilayer coating systems. The test involves vertically bonding a pull-off head to the coating surface and applying a pulling force until the coating separates, measuring the required force to evaluate adhesion strength.
Sag resistance and leveling in constructability evaluation
This article primarily discusses how to balance the two key properties of sag resistance and leveling during the application of materials such as coatings and adhesives. Sag resistance refers to the material's ability to resist sagging due to gravity on vertical surfaces, while leveling refers to the material's ability to automatically smooth out its surface after application.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
What are the differences between horizontal airflow and vertical airflow in a clean bench?
Purification workbenches primarily employ two types of air supply methods: horizontal and vertical. In horizontal air supply, the airflow is parallel to the work surface, while in vertical air supply, the airflow moves from top to bottom, forming a laminar barrier. The selection should be based on a comprehensive consideration of experimental needs, sample characteristics, and safety requirements.
The softness tester can show a data difference of up to 30% when measuring paper hand-feel samples taken from different directions.
This article mainly discusses that when testing the softness of paper, if samples are taken along different directions, such as the machine direction (longitudinal) and the cross direction (transverse), the measured data can vary significantly, sometimes by as much as 30%.