Wire Fault Locator

The wire fault detector transmits high-frequency electromagnetic waves to inspect the internal structure of wires. When these waves encounter breaks or corrosion, they generate reflected signals. The instrument analyzes the characteristics of these signals to locate the damage points. It is used to identify insulation damage and conductor breaks in underground cables and building wiring.
Selection
Select the appropriate measurement range based on the voltage level of the wire under test. For metal wires, eddy current methods are preferred, while time-domain reflectometry is used for non-metallic materials. In humid environments, verify the protection rating, and for long-distance detection, ensure the waveform refresh rate is higher than once per second.

Terms

Standards

Instruments

Using wire-wound stainless steel wire structure, the film thickness is 100 microns, the total length is 375mm, and the application width is 255mm to ensure that the Spreader is uniform and firm, suitable for precision experimental operation.

$ 173.00

Wire-wound design wet film thickness 11.4μm, wire diaMeter Φ 0.13mm, not easy to block and easy to clean, suitable for a variety of substrates, to achieve uniform Spreader and flexible thickness adjustment.

$ 525.00

Wire-wound design wet film thickness 9.1 μ m, steel wire diaMeter Φ 0.10mm, chrome-plated surface is easy to clean and prolong life, suitable for a variety of substrates, Spreader uniform and flexible.

$ 525.00

Suitable for diaMeter 0.1 to 4mm wire, Measurement range 0.03-50 microns, resolution 0.01 microns, equipped with thermal printer and quick installation fixed table, easy and accurate operation.

$ 2042.00

With 10-60 times/min adjustable speed rate and 10 ° -360 ° adjustable angle, supports 6-station synchronous testing, simulates the bending tensile stress of the wire through reciprocating rocking, and evaluates durability.

$ 1390.00

Support 2-wire method and 3-wire method measurement, Ground Voltage Measurement range 0~ 200V, Ground Resistance Measurement range 0~ 199.9 Ω, Response Time about 5 seconds, with continuous measurement function and overload protection, suitable for a variety of grounding system testing.

$ 138.00

Maximum load 5KN, suitable for wire tensile testing, strong clamping and accurate measurement, to meet a variety of material testing needs.

$ 217.00

Maximum load 5KN, suitable for tensile testing of wire materials, with precise clamping function to ensure accurate and reliable test data.

$ 169.00

Wire-wound design, wet film thickness of 102.9μm, wire diaMeter Φ 1.14mm, effective application width 1500mm, not easy to block and easy to clean, suitable for high viscosity coatings.

$ 719.00

A wet film of 148.6 μm can be prepared using a wire-wound process with a 1.65 mm wire diaMeter, ensuring accurate and durable coating while preventing wire breakage issues.

$ 167.00

Using 0.06mm ultra-fine stainless steel wire, the wire diaMeter is thinner than the common 0.07mm in the market, the bristles are soft and can be deeply cleaned without damaging the roller surface, suitable for fine cleaning applications.

$ 135.00

Wire-wound process is prepared with 6.9 μm wet-film, and the diaMeter of the steel wire is only 0.08mm. If the hair is thin, seamless winding reduces the risk of broken wire, and is suitable for a variety of fluid Spreader applications.

$ 186.00

Using 180 * 480mm size, with wire Rod or Film Applicator scraping ink, is conducive to the film flat and effective, improve film mass.

$ 122.00

Utilizing a wire-wound design, it controls the wet film thickness with a 0.61mm steel wire diaMeter, features a coating width of 300mm, and is constructed from durable stainless steel.

$ 167.00

Wire-wound structure wound stainless steel wire, firm and reliable; one operation can simultaneously Spreader two or more Coatings; diaMeter 9mm, total length 245mm, application width 140mm.

$ 157.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
DSC analyzer measures the glass transition of degradable films.
This article explains how to use a differential scanning calorimeter to measure the glass transition temperature of a degradable film. It first clarifies that the glass transition is the process by which a material changes from a glassy state to a highly elastic state, which appears as a baseline shift on the curve.