Droplet Thickness Gauge

The droplet thickness gauge measures the thickness of coating droplets on a substrate using optical or capacitive sensors. It is used to monitor coating uniformity in printing and coating processes and is suitable for quality control of materials such as paper and plastic films.

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Glass grinding liquid interface and silver ion capture hydrazine structure, Measurement range 1-12pH, Temperature range 0-60 ℃, suitable for object surface and droplet sample detection.

$ 251.00

With emission-echo and echo-echo two thickness measurement modes, Measurement range 0.65~ 600mm, Probe type can be automatically identified and zero point calibrated, support anti-measurement Speed of sound function to improve accuracy.

$ 667.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Measurement of nonmagnetic coatings on ferrous metals, thickness range 0-6000μm, accuracy +/- 3%, built-in Probe single-handed operation, Protection Rating IP65, 60 + readings per minute.

$ 1022.00

Measurement range 1.2~ 225mm, support Speed of sound measurement and 12 data storage functions, with upper and lower limit alarm settings and coupling status prompts, suitable for a variety of material thickness detection.

$ 223.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

Using microprocessor technology implementation 0.7-400 mm thickness measurement, resolution is +/- 0.01mm, support five Probe options, with automatic shutdown and backlight display function.

$ 577.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Measurement range with 0.01mm high resolution and 0.65-400 mm width supports Probe automatic identification and multiple Measurement modes, which can penetrate the thickness of the coating measurement substrate and realize the data freezing display.

$ 1610.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.

$ 401.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Contact angle measuring instrument measures the surface energy of resin after curing.
The contact angle measuring instrument evaluates surface energy by analyzing the contact angle formed by a droplet on a solid surface, based on the principle of Young's equation. Measuring the surface energy of resin after curing is significant for properties such as coating adhesion and bonding.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Contact Angle Meter Evaluates Wettability of Hydrophobic Coatings
A contact angle measuring instrument evaluates the wettability of hydrophobic coatings by analyzing the angle formed by a liquid droplet on a solid surface. Its principle is based on Young's equation, where a contact angle greater than 90° indicates hydrophobicity.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Contact angle measuring instrument measures the surface wettability of paper.
The contact angle goniometer evaluates wettability by measuring the contact angle of a liquid droplet on the surface of paper, based on the principle of Young's equation. The static drop method is commonly used for measurement, requiring control over sample flatness, environmental conditions, and droplet volume, while also considering the influence of surface roughness.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.