Flame AA SpectroMeter

The flame atomic absorption spectrometer atomizes samples by spraying them into a flame, and after atomization, the elements absorb light at specific wavelengths. The absorbance is measured to quantitatively analyze metal elements. It is used to detect heavy metal content such as lead and cadmium in coatings and inks, as well as to monitor raw material impurities in the plastics and paper industries.
Selection
Select the corresponding light source based on the types of elements to be detected, consider the sample matrix to match the burner type, determine the precision of the atomization system according to detection limit requirements, adapt the sample throughput to automatic sampling functions, and configure safety protection based on the operating environment.

Terms

Standards

Instruments

Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.

$ 820.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.

$ 2655.00

Adopt low friction bearing impeller Sensor, support wind speed, wind temperature, wave height, wind level and air volume measurement, with 24 data storage and 0-9 minutes adjustable automatic shutdown function, Sampling rate about 1 second.

$ 172.00

Adopting non-vacuum design, equipped with Mo target and electric refrigeration detector, with seven kinds of light path automatic switching and multiple radiation protection, to ensure efficient and safe testing.

$ 15887.00

Measurement unit conversion function, support 24 data storage, Ultra low friction bearing Sensor to ensure high Sensitivity and accurate measurement, wind speed measurement handle can be separated from the fuselage for easy operation.

$ 243.00

1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.

$ 1219.00

45 ° Measurement Angles, 0~ 199.9GU Measurement range, ultra-small portable design only 180g, a AA battery can be used continuously for 60 hours, moisture-proof process adapts to harsh environment, immediately measure without drift.

$ 506.00

The equipment adopts stainless steel structure to resist corrosion, equipped with automatic ignition and Timing function, combustion time 0~ 99.99 seconds, gas lamp Nozzle inner diaMeter 9.5mm, to ensure accurate and reliable testing.

$ 670.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.

$ 2655.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.

$ 2171.00

Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.

$ 946.00

Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.

$ 1493.00

Using dual Sensor temperature measurement system, the maximum operating temperature is 380 ℃, Temperature range environment temperature to 380 ℃, support continuous work, large heating area and no open flame design.

$ 140.00

Dual channel LED digital display ensures clear reading, using silicon Photocell, photovoltaic cell detection to make the measurement results accurate and stable, Response Time is less than 8 seconds and has flameout protection function, safe and reliable operation.

$ 1332.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, Stability relative change within 15 seconds ≤ 2%.

$ 3543.00