Continuous Hot Melt Adhesive Coating Testing Machine

The continuous hot melt adhesive coating tester heats and melts solid adhesive material, which is then uniformly applied onto the substrate surface through a coating head, forming an adhesive layer upon cooling and solidification. It is used to simulate production line coating processes, test the coating performance and parameters of adhesives on various substrates, and is suitable for product development and quality control in industries such as packaging and textiles.
Selection
When selecting, consider whether the coating width and speed range match the sample size. The temperature control accuracy must meet the requirements for adhesive melting, and the coating head type should be compatible with the expected coating morphology. Pay attention to substrate compatibility and the stability of the tension control system to ensure the equipment can simulate actual production conditions. The operation interface should be simple and intuitive, facilitating parameter adjustments and data recording.

Terms

Standards

Instruments

The thickness range of Spreader is 0.01mm~ 2mm, the minimum gluing thickness is 0.01mm, the coating surface density ≤ +/- 1.5%, the dial Meter is used to fine-tune the gap and the Teflon baffle to adjust the width, and it supports forward and reverse continuously variable speed and automatic winding.

$ 4269.00

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

High Accuracy modular Spreader station structure, Spreader thickness range of 0.01mm to 2mm, coating speed 2-4.5 m/min adjustable, support forward and reverse stepless variable speed and automatic winding, gap adjustment Graduation up to 0.001mm, easy to accurately control the Spreader process.

$ 5399.00

The equipment adopts High Accuracy modular Spreader station, all-electric control without air source, minimum glue thickness 0.01mm, Spreader speed 2-4.5 m/min adjustable, with electronic control precision tension to adapt to a variety of materials such as paper, plastic and metal film.

$ 5721.00

Coating speed 1~ 10m/min adjustable, Spreader thickness range of 0.005-3mm, drying temperature up to 200 ℃, equipped with infrared drying and air cooling system to achieve efficient Spreader and drying.

$ 51711.00

The equipment supports 400mm maximum Spreader width, Spreader thickness 0.01-2 mm adjustable, with forward and reverse stepless speed change and automatic winding function. The rubber groove and upper rubber wheel can be quickly disassembled and cleaned to adapt to different material tension control needs.

$ 37188.00

Wet film thickness adjustment range 0.005-3mm, Spreader accuracy +/- 5%, using servo drive and PLC control to achieve 1-10m/min adjustable coating speed, with automatic tension control and hot air circulation oven.

$ 21051.00

Maximum Spreader width up to 1000mm, Spreader speed 1-10m/min adjustable, support unlimited length Spreader and automatic winding, forward and reverse stepless speed change, discharge and receiving reel tension adjustable, heating Rod and glue slot can be quickly disassembled to clean up residual glue.

$ 29120.00

Equipped with a universal joint device to make the page even and avoid tearing; the upper limit setting function of the force value can automatically return to protect the page when the set value is reached; Measurement range 0-300N, accuracy +/- 1%; support 5-120mm/min speed adjustable.

$ 3507.00

Temperature control accuracy of +/- 0.5 ℃, equipped with eight standard test force, can accurately determine the melt flow performance of polymers at high temperatures, to meet a variety of material testing needs.

$ 977.00

Adopting MCU to adjust power and temperature control mode, temperature control accuracy +/- 0.5 ℃, with eight standard test force, can meet the needs of different material testing, suitable for melt flow performance measurement at high temperature.

$ 945.00

Can measure 50~ 200000mPa · s viscosity range, Temperature control accuracy of +/- 0.1 ℃, the use of high subdivision stepper motor to ensure smooth Rotation speed, support the whole process of monitoring viscosity - Linear dispersion, beyond the range of automatic alarm.

$ 1645.00

Adopt High Accuracy modular Spreader station structure, all-electric control without external air source; Spreader thickness can reach a minimum of 0.01mm, accuracy +/- 0.003mm; equipped with UV LED curing module, instant curing; Spreader width 400mm, speed 2-4.5 m/min adjustable, forward and reverse stepless transmission.

$ 9755.00

Adopt all-electric control without external air source, Spreader thickness range 0.01mm to 2mm, Spreader speed 2-4.5 m/min adjustable, with quick-release plastic groove and precision tension control, suitable for paper, film and other substrates.

$ 9433.00

The equipment adopts High Accuracy modular Spreader station, Spreader thickness range 0.01mm~ 2mm, coating speed 2~ 4.5m/min adjustable, with UV instant curing and heating function, suitable for a variety of materials such as paper, film and so on.

$ 10562.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.