Color-Change Temperature Indicator

Color-changing temperature measurement strips are based on the principle that thermosensitive materials change color upon heating, allowing the surface temperature of an object to be determined through visual comparison with a color scale. They are used for rapid on-site temperature measurement applications such as equipment overheating monitoring and welding temperature control.
Selection
Select the measurement range based on the highest temperature resistance of the object being tested, consider the curvature and material of the attachment surface, determine the size according to the observation distance, be aware that ambient light affects color interpretation accuracy, and decide the procurement quantity based on the single-use characteristics.

Terms

Standards

Instruments

Provides 188 ℃ temperature history, irreversible color change, accuracy is +/- 1 ℃ within 100 ℃, oil and water and steam resistance, Instant Response and easy to use.

$ 98.00

Adopt irreversible color changing technology, accuracy +/- 1-4 ° C, oil and water resistance and steam resistance, provide four-grid temperature monitoring, size 23x45mm, 10 sheets each, easy to record temperature history for a long time.

$ 93.00

Using irreversible color technology, temperature accuracy +/- 1.5 ℃, Response instant, oil water and steam resistance, size 12 * 13mm circular single grid design, 50 sheets per book for easy use.

$ 96.00

Four-grid temperature sensitive element with +/- 1 ° C accuracy below 100 ° C, providing irreversible Color change, oil, water and steam resistance, Instant Response to temperature changes.

$ 93.00

Irreversible color change records the highest temperature, silver to black obvious change, accuracy +/- 4 ℃, oil water and steam resistance, Instant Response and easy to use.

$ 98.00

Immediate Temperature Response with Irreversible Color Changing Technology, Measurement accuracy +/- 1 ° C to +/- 4 ° C, Resistant to Oil, Water and Steam, Provides Long-term Temperature Record for Easy Paste and Preservation.

$ 96.00

Measuring temperature 90 ℃ and the error is only +/- 1 ℃, the melting state can be observed at a distance, directly pasted and used to visually display the overheating of the equipment.

$ 89.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure Temperature Uniformity ≤ 2 ° C, with remote monitoring function.

$ 28119.00

Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.

$ 13064.00

Using irreversible discoloration technology, providing 5-grid temperature measurement from 60 ° C to 82 ° C, Response is fast and oil and water vapor resistant, accuracy is +/- 1 ° C below 100 ° C.

$ 98.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, reduce energy consumption and noise through frequency conversion technology, and support 120 sets of program editing and remote monitoring functions.

$ 28119.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and is equipped with a two-stage throttling system and a forced air duct to ensure temperature uniformity ≤ 2 ° C. Remote visual control and fault self-diagnosis functions are supported through RS485 communication.

$ 20599.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.

$ 25973.00

Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.

$ 9836.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Temperature Paper Selection: Temperature Gradation and Response Speed Evaluation
This article mainly discusses how to choose the right temperature measurement paper. It points out that two key parameters should be considered during selection: the temperature steps and the response speed.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
High Pressure Accelerated Aging Tester Evaluation of Paint Resistance to High Temperature, High Humidity, and High Pressure Environments
This article introduces how a high-pressure accelerated aging test machine evaluates the durability of colored paint under high temperature, high humidity, and high-pressure conditions. The test machine simulates these conditions to accelerate the aging of the coating and observe whether issues such as discoloration or blistering occur.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.