Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.
Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.
Imported cold light source technology life of 100,000 hours, support 0.001mg/L high Sensitivity detection, with digestion Colorimetric integrated tube design to achieve safe and fast measurement, can store 4000 sets of data and support multi-mode power supply.
Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.
Colorimetric integrated tube design, sample digestion and result reading share a tube, no need to transfer liquid; more than 10 measurements of water samples and removal of abnormal values are averaged to reduce errors; built-in two COD detection methods, Measurement range 0-20000mg/L, detection limit as low as 2mg/L.
Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.
Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.
Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.
With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.
Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.
Colorimetric digestion integrated tube, no need to transfer the liquid, directly display the concentration value; support more than 10 measurements to take the average value, reduce the error; measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, Optical inspection Stability, life up to 100,000 hours.
Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.
Measurement range 0.00~ 9.99 ppm, accuracy +/- 0.05 ppm, LED Illuminant 470 nm, automatic shutdown function, compact and portable design.