Asphalt Flash Point Tester

The asphalt flash point tester heats the sample and introduces a test flame to detect the lowest temperature at which the combustible vapors released by the asphalt, mixed with air, ignite upon encountering an ignition source. It is used to assess the fire hazard of asphalt during storage, transportation, and use, and is commonly employed in road construction and waterproof material production.
Selection
When selecting an asphalt flash point tester, consider the compatibility between sample characteristics and testing standards, ensuring that the heating rate and ignition method meet regulatory requirements. Pay attention to temperature control accuracy and detection repeatability, and ensure the equipment materials are corrosion-resistant. The operation interface should be user-friendly, and maintenance components should be easy to replace. Determine the instrument capacity specifications based on daily testing volume.

Terms

Standards

Instruments

Using electronic ignition and flash detection module, test process automation, Temperature range RT +~ 400 ℃, Repeatability +/- 4 ℃, with over-temperature protection and anti-dry burning function.

$ 5399.00

It adopts copper ring and steel ball structure, supports 2-3.55 gram steel ball configuration, and accurately determines the softening temperature of the material through the drop distance of 25.4 mm, which is suitable for all kinds of asphalt experiment needs.

$ 122.00

Using 7-inch true color Touchscreen and 32-bit microprocessor, Temperature range RT +~ 400 ℃, with automatic atmospheric pressure compensation and over-temperature protection function, the test process is fully automated.

$ 5399.00

Adopt ARM microprocessor and color LCD display, with automatic heating, sweeping, ignition function, Repeatability ≤ 110 ℃ +/- 1 ℃, support atmospheric pressure correction and forced Air-Cooled, easy and reliable operation.

$ 2116.00

Using ARM microprocessor and German technology, the test can be completed with only 1-2ml of trace samples. With automatic heating, sweeping, ignition and printing functions, no external combustible gas is required, and the operation is simple and reliable.

$ 4269.00

Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.

$ 1719.00

Using ARM microprocessor and color liquid crystal display, with automatic heating sweep ignition function, Temperature range 40~ 400 ℃, can store 1000 measurement results, support atmospheric pressure correction and forced Air-Cooled.

$ 2116.00

Measurement range 50~ 40000FPM, accuracy +/- 0.05% n + 1d, Sampling time 0.3 seconds. With automatic stop flash to extend life, external trigger to achieve automatic pattern tracking, accurate measurement Rotation speed without contact.

$ 344.00

Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.

$ 696.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.

$ 696.00

With 5 point button Adjustment, Measurement accuracy of 1% F. S, Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, equipped with USB interface for data transmission.

$ 696.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

Measurement range of 50~ 7600 μm, error +/- 3%, suitable for thick soft coatings such as polyurea and asphalt neoprene, providing accurate thickness detection.

$ 3226.00

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Measurement accuracy of 1% F. S and 1 × 10~ 0.1M wide range, support 5 point calibrating, automatic temperature compensation and 500 data storage, built-in clock conforms to GLP specifications.

$ 696.00

Articles

Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
How to Choose Between the Ring and Ball Method and the Cup and Ball Method for Softening Point Testers? Read This and Stop Worrying
This article introduces two main methods for determining the softening point of materials: the ring-and-ball method and the cup-and-ball method. The ring-and-ball method is more widely used and is suitable for materials such as asphalt. It involves measuring the temperature at which a steel ball causes the sample to sink. The cup-and-ball method is often used for specific resins or wax products, relying on the flow of the sample or the penetration of a steel ball to determine the endpoint.