Infrared Water Content Meter

The infrared moisture meter utilizes the absorption characteristics of moisture for specific infrared bands to calculate moisture content by measuring changes in the intensity of infrared light reflected or transmitted by the sample. It is used for rapid detection of moisture control during the production of materials such as coatings and plastics.
Selection
When selecting, consider the sample form’s compatibility with transmission or reflection modes, ensure the moisture measurement range covers actual needs, verify that the accuracy meets process control requirements, pay attention to the environmental temperature compensation function, and check the instrument calibration method and maintenance convenience.

Terms

Standards

Instruments

Equipped with infrared CO2 sensor accuracy of 0.1%, Water-jacketed heating ensures temperature stability, built-in ultraviolet sterilization function effectively prevents pollution, supports programmed control and data recording.

$ 3436.00

Equipped with infrared CO2 sensor accuracy of 0.1%, Water-jacketed heating to ensure stable temperature, built-in UV sterilization lamp and microbial Filter, effectively prevent foster pollution, support RS-485 data connection.

$ 1693.00

Equipped with infrared CO2 sensor accuracy of 0.1%, Water-jacketed heating to ensure temperature stability, built-in ultraviolet sterilization function and microbial Filter, effectively prevent foster pollution, support three-shelf and intelligent program control.

$ 2368.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.

$ 567.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

4 groups of samples can be tested at the same time, using PID temperature control accuracy of 0.1 ℃, support segmented program heating, one key automatic calculation of carbon black and ash content, open the lid structure heat dissipation fast.

$ 2784.00

The thermal weight loss method is used to measure carbon black content, the operating temperature can reach 990 ° C, and the 7-inch Touchscreen is equipped to realize one-button calculation, support segmented paraMeter setting, and the Furnace body separation design has better heat dissipation.

$ 1848.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.